Thermal Adjustable Type MCCB
- Contact Us
- Address: Shanghai DaDa Electric Co.,Ltd.
- Phone: 0086-15167477792
- Email: charlotte.weng@cdada.com
DAM1 series adjustable range of Moulded Case Circuit Breakers are designed and manufactured to world-class standards.Provide overload and short-circuit protection for all applications.The thermal elements, adjustable over a wide band,make these MCCBs ideal for any distribution application.
Advantages
• 16A to 1600A in 6 frame sizes in three pole and four pole with switched execution.
• Compact dimensions
• Adjustable thermal setting(70-100%)In.
• Push to trip button provision.
• Separate main and arcing contacts
• Wide range of accessories.
Electrical Parameters Of DAM1 MCCB Adjustable Type Molded Case Ccircuit Breaker
Thermal adjustable type MCCB (0.7-1)In |
|
|
|
|
|
|
|||
Photo |
Model |
code |
Icu(KA) |
Ic(KA) |
Rated Current-In |
Ui(V) |
Ue(V) |
Pole |
Uimp(V) |
|
DAM1-160 |
B |
25 |
12.5 |
10-12,5-16-20-25-32-40-50-63-80-100-125-160(150)A |
750V |
400/415V |
3P/4P |
8000 |
N |
35 |
26.25 |
|||||||
S |
50 |
37.5 |
|||||||
|
DAM1-250 |
N |
35 |
26.25 |
63 – 80-100-125 – 160(180) - 200(225) – 250(320)A |
750V |
400/415V |
3P/4P |
8000 |
S |
50 |
37.5 |
|||||||
H |
65 |
48.75 |
|||||||
G |
85 |
51 |
|||||||
|
DAM1-630(400) |
N |
35 |
26.25 |
250 – 315 (350)- 400 – 500 - 630A |
750V |
400/415V |
3P/4P |
8000 |
S |
50 |
37.5 |
|||||||
H |
70 |
52.5 |
|||||||
G |
85 |
52.5 |
|||||||
|
DAM1-800 |
N |
35 |
35 |
400 – 500 – 630 (700)- 800 -1000A |
750V |
400/415V |
3P/4P |
8000 |
S |
50 |
37.5 |
|||||||
H |
70 |
52.5 |
|||||||
G |
85 |
52.5 |
|||||||
|
DAM1-1600 |
S |
65 |
50 |
800 -1000 – 1250 – 1600A |
750V |
400V |
3P/4P |
8000 |
H |
85 |
50 |
|||||||
G |
100 |
50 |
• Icu:O-t-CO test(O:Open maneuver,CO:Close-Open maneuver,t:Waiting duration)
• Ics:O-t-CO-t-CO test(O:open maneuver,CO:Close-Open maneuver,t:Waiting duration)
Physical Parameters Of Dam1 MCCB Molded Case Circuit Breaker
Category (EN 60947-2/IEC 60947-2) |
Endurance |
|
|
|||||
Model |
Pole |
Dielectric Propery (V) |
lonization distance (mm) |
Total Cycles |
Electrical Life |
Mechanical Life |
Main circuit |
Auxiliary circuit |
DAM1-160 |
3P / 4P |
3000 |
≤30/0 |
8000 |
1000 |
7000 |
|
AC-15 |
DAM1-250 |
3P / 4P |
3000 |
≤30/0※ |
8000 |
1000 |
7000 |
|
AC-15 |
DAM1-630(400) |
3P / 4P |
3000 |
≤60/0※ |
5000 |
1000 |
4000 |
|
AC-15 |
DAM1-800 |
3P / 4P |
3000 |
≤80/0※ |
5000 |
1000 |
4000 |
|
AC-15 |
DAM1-1600 |
3P / 4P |
3000 |
≤80/0※ |
3000 |
500 |
2500 |
|
AC-15 |
Size Of MCCB Molded Case Circuit Breaker
Model |
Pole |
Outline dimension(LXWXH) |
Drawings |
DAM1-160 |
3P |
120x90x70mm |
|
4P |
120x120x70mm |
||
DAM1-250 |
3P |
170x105x103.5mm |
|
4P |
170x140x103.5mm |
||
DAM1-630(400) |
3P |
254x140x103.5mm |
|
4P |
254x184x103.5mm |
||
DAM1-800 |
3P |
268x210x103.5mm |
|
4P |
268x280x103.5mm |
||
DAM1-1600 |
3P |
410x210x138.5mm |
|
4P |
410x280x138.5mm |