The incredibly rich projects administration experiences and a person to 1 service model make the substantial importance of organization communication and our easy understanding of your expectations for 2 Pole Circuit Breaker, 3 Phase Circuit Breaker, Double Circuit Breaker, Our aim is to help customers realize their goals. We are making great efforts to achieve this win-win situation and sincerely welcome you to join us!
Renewable Design for Time Delay Circuit Breaker - C45 2P Miniature Circuit Breaker – DaDa Detail:

Application

C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898.

Main Technical Parameter

Type C45
Pole 1P 2P,3P,4P
Rated current (A) 6,10,16,20,25,32,40,50,63
Rated voltage (V) 230 400
Ambient temperature -5oC~+40oC
Type of instantaneous release C D C D
Rated short circuit breaking capacity Icn(kA) 1-32A:6
50-63A:4
4 1-32A:6
50-63A:4
4

Applicable Conducting Wire

Rated current(A) Norminal cross section of wire mm2
1-6A 1
10A 1.5
16,20A 2.5
25A 4
32A 6
40,50A 10
63A 16

The Over-Current Protection Property

Ambient Temperature

Initial Status

Test Current

Expected Result

Expected Result

Note

30±2oC

Cold position

1.13In

t≥1h

Non-release

-

Carried out immediatelyafter previous test

1.45In

t < 1h

Release

-

Cold position

2.55In

1s < t< 60s(In≥32A)

Release

Current smoothly rises tospecified value within 5s

Cold position

2.55In

1s < t < 120s(In>32A)

Release

-5~+40oC

Cold position

3In

t≥0.1s

Non-release

Type B

Cold position

5In

t < 0.1s

Release

Type B

Cold position

5In

t≥0.1s

Non-release

Type C

Cold position

10In

t < 0.1s

Release

Type C

Cold position

10In

t≥0.1s

Non-release

Type D

Cold position

20In

t < 0.1s

Release

Type D


Product detail pictures:

Renewable Design for Time Delay Circuit Breaker - C45 2P Miniature Circuit Breaker – DaDa detail pictures

Renewable Design for Time Delay Circuit Breaker - C45 2P Miniature Circuit Breaker – DaDa detail pictures

Renewable Design for Time Delay Circuit Breaker - C45 2P Miniature Circuit Breaker – DaDa detail pictures

Renewable Design for Time Delay Circuit Breaker - C45 2P Miniature Circuit Breaker – DaDa detail pictures

Renewable Design for Time Delay Circuit Breaker - C45 2P Miniature Circuit Breaker – DaDa detail pictures


Related Product Guide:

With our loaded encounter and considerate services, we have now been recognized as a trustworthy supplier for lots of worldwide consumers for Renewable Design for Time Delay Circuit Breaker - C45 2P Miniature Circuit Breaker – DaDa , The product will supply to all over the world, such as: Toronto, Surabaya, Denmark, We have advanced production technology, and pursuit innovative in products. At the same time, the good service has enhanced the good reputation. We believe that as long as you understand our product, you must be willing to become partners with us. Looking forward to your inquiry.
  • We always believe that the details decides the company's product quality, in this respect, the company conform our requirements and the goods are meet our expectations.
    5 Stars By Phoebe from Brasilia - 2018.11.02 11:11
    After the signing of the contract, we received satisfactory goods in a short term, this is a commendable manufacturer.
    5 Stars By Lindsay from Manila - 2017.06.16 18:23
    Write your message here and send it to us