product

  • DAL3-63 Residual Current Circuit Breaker(RCCB)

    DAL3-63 Residual Current Circuit Breaker(RCCB)

    Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)...
  • DAL2-63 Residual Current Circuit Breaker(RCCB)

    DAL2-63 Residual Current Circuit Breaker(RCCB)

    Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)...
  • DAB6LE-63 Series Earth Leakage Circuit Breaker(ELCB)

    DAB6LE-63 Series Earth Leakage Circuit Breaker(ELCB)

    Advantages • Compact structure, small size, 2 modules wide. • It has neutral line breaking function, more secure and reliable. • It has dual-purpose terminal with strong connection ability. • It has the contact status indicator, easy to identify the contact condition. • Can be used with a variety of accessories, and used for overvoltage protection. Physical Parameters Of DAB6LE-63 Residual Current Device Standard of conformity: IEC61009 (EN61009) and GB16917.1 Sensitivity: type A, type AC Rel...
  • DAB6LE-63 Series Earth Leakage Circuit Breaker(ELCB)

    DAB6LE-63 Series Earth Leakage Circuit Breaker(ELCB)

    Advantages • Compact structure, small size, 2 modules wide. • It has neutral line breaking function, more secure and reliable. • It has dual-purpose terminal with strong connection ability. • It has the contact status indicator, easy to identify the contact condition. • Can be used with a variety of accessories, and used for overvoltage protection. Physical Parameters Of DAB6LE-63 Residual Current Device Standard of conformity: IEC61009 (EN61009) and GB16917.1 Sensitivity: type A, type AC Rel...
  • DAF360 Series Residual Current Circuit Breakers

    DAF360 Series Residual Current Circuit Breakers

    The DAF360 electronic residual current circuit breaker has been designed and manufactured in accordance with the latest IEC61008-1 standards and complies with the EN50022 standards for modular switches. They can be used to load standard guide rails with “hat shape” symmetrical structures.
  • DAL1-63 Residual Current Circuit Breakers

    DAL1-63 Residual Current Circuit Breakers

    Introduction DAL1-63 residual current circuit breakers are protection equipment which must be used to protect human life against dangerous electric shocks or prevent the fires arising out of isolation mistakes thereby detecting isolation mistakes to occur within the plant in advance. Sigma residual current circuit breakers are produced with 2 and 4 poles in accordance with IEC EN 61008-1 standard and in compliance with CE norms under ISO 9001:2008 quality assurance system. What is the differe...
  • DABL-63 RCBO 6KA Residual Current Operated Circuit Breaker

    DABL-63 RCBO 6KA Residual Current Operated Circuit Breaker

    Residual current operated circuit breakers with overcurrent protectionDABL-40are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection.
    They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting.
  • DABL-63 Nova Series Residual Current Operated Circuit Breakers With Overcurrent Protection

    DABL-63 Nova Series Residual Current Operated Circuit Breakers With Overcurrent Protection

    Residual current operated circuit breakers with overcurrent protectionDABL-40are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection.
    They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting.
  • DAB7LN-40 series DPN Residual Current Operation Circuit Breaker(RCBO)

    DAB7LN-40 series DPN Residual Current Operation Circuit Breaker(RCBO)

    DAB7LN -40 residual current circuit breakers are small devices designed with high breaking capacity (6kA) and they are suitable for the disconnection of neutral lines.The circuit breakers are widely used in AC50H low-voltage electrical systems with a rated voltage of 230V and rated current of no more than 40A. This effectively protects people from electric shock and circuit equipment form overcurrent or short circuiting.These circuit breakers are also suitable for preventing fire hazards as a result of ground currents caused by insulation damage of electrical equipment.
  • RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection

    RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection

    Introduction Residual current operated circuit breakers with overcurrent protection ABDT-63 are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection.  They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting.
  • MCB Under Voltage Release

    MCB Under Voltage Release

    Under voltage release
    The rated voltage is 230V and 400V respectively. The release will break the circuit breaker when the actual voltage is between 70%Ue-35%Ue; the release will prevent the circuit breaker from closing when the actual voltage is below 35%Ue; the release will close the circuit breaker when the actual voltage is between 85%Ue-110%Ue.
  • MCB Shunt Release

    MCB Shunt Release

    Shunt release
    Rated control source voltage(Us)of DAB7-FL shunt release is AC50Hz and 24V to 110V, 110V to 400V,DC 24V to 60V, 110V to 220V, when the applied current voltage is from 70% Us to 110% Us, the shunt release will act reliably and break the circuit breaker.