Modular Plastic Empty Enclosure For MCB IP40 (TXM series) Plastic base
Overall panel design is luxury and attractive, the face covering colors are dark green and brawn (provided according to the color needs of the different interior residential designs except for the standard colors). The design of the face covering gives a noble and elegant feeling. lure Ivory, high Strength, never change color.Transparent material is PC. Fixed frame, simple structure, and easy installation. -
DAM1 -160L ELCB Earth Leakage protection circuit breaker1
DAM1L series residual current (leakage) circuit breaker (hereinafter referred to as circuit breaker) is a new series of residual current (leakage) successfully developed by using international standard design and advanced manufacturing technology.
Protected moulded case type circuit breaker.
The rated insulation voltage of circuit breakers of this series is 400V (Inm is less than 160A) and 690V (Inm is more than 250A), which is mainly used for ac 50Hz and rated In a power distribution network with a current of 10A~500A and a rated working voltage of 380V/400V, it is used to distribute electric energy and protect the overload and short circuit of lines and power equipment.Under normal conditions,It can also be used for infrequent switching of lines. -
Rotary Handle Mechanism
Handle Operating Mechanism Series Rotary handle operating mechanism The rotary handle operating mechanism suitable for: 1. Closing and Opening of MCCB by the rotary handle on MCCB 2. Closing and Opening of MCCB by the rotary handle on the compartment door of switch board: 3. Interlocking between handle the rotary operating mechanism and compartment door to prevent the compartment door from being opened in case of MCCB in closed state. Customer can fit padlock on it for MCCB in open position... -
Shunt Release
The shunt release is intended for remote controlling of opera of MCCB Release instantaneous duty. Characteristics of Shunt release: Electricalaccessories Shunt release Range ofsupply voltage (0.7-1.1)) x Us Rated controlsupply voltage us Power supply AC 50Hz 220V 380V Power loss 150V 150V DC 110V 220V Power loss 150V Wiring diagram of Shunt release: SB2- Opening Push-putton(ready by user ) P3,P4- Terminal number Us- Control power QF -Au... -
Electrical Operating Mechanism (Motor)
DAM1(ABB) Electrical Operating Mechanism The electrical operating mechanism is available remote close of MCCB The types of electrical operating mechanism are shown in table 2 Types Of Electrical Operating Mechanism: Table 2 Rated current of frame size Inm Types of electrical Operating Mechanism CD1 CD2 CD3 CD 63A - CD2-63 - - 100A - CD2-100 - - 160A - CD2-160 - - 250A CD1-250 CD2-250 - CD-250 400A CD1-400 - - CD-400... -
Under Voltage Release
Application The under voltage is intended for under voltage protection of circuit and electric equipment. Release uniterrupted duty. Characteristics of under voltage release: Ue(V)Rated operation voltage AC380 AC220 DC110 DC220 Operation voltage (0.35-0.7)) x Ue Ensured closing voltage (0.85-1.1)) x Ue Ensured non closing voltage ≤0.35 Ue Power loss 10VA 4W Wiring Diagram Of Under Voltagerelease Us- Control power P1,P2- Terminal number ... -
Auxiliary contact Alarm contact
Application The auxiliary contacts is intended for automatical controlling of the auxiliary circuit of MCCB,and open action of current,and under voltage of circuit and equipment. Auxiliary And Alarm Contacts Size 1N/O and 1N/C+1alarm contact 2N/O and2N/C+1alarm contact Wiring Diagram Of Auxiliary And Alarm Contacts State of MCCB State of alarm contacts diagram of wiring Close position Explanation Us1 is auxiliary power Us2 is alarm power Open position Explanat... -
Auxiliary Contacts
Application The auxiliary contacts is intended for automatical controlling of the auxiliary circuit of MCCB,such as indication of the open and close states of MCCB. Auxiliary Contacts Size 1N/O and 1N/C 2N/O and2N/C 4N/O and 4N/C Wiring Diagram Of Auxiliary Contacts State of MCCB State ofauxiliary contacts diagram of wiring Close position 1 set of auxiliary contacts,but2 sets of contacts to be supplied For Inm=63A-225A 2 set of auxiliary contacts,but4 sets... -
Alarm Contacts
Alarm Contacts Application The alarm contacts is used for alarm open action of current ,and under voltage of circuit and equipment. Alarm contacts size: 1N/O and 1N/C Wiring Diagram Of Auxiliary Contacts: State of MCCB State of alarm contacts diagram of wiring Close position Open position DAM1-125/160BC DAM1(ABB)-125,160A DAM1-250/400BCDAM1(ABB)-250A,400A DZ20-100BCDZ20-100A DZ20-225BC DZ20-225A ... -
Modular Plastic Empty Enclosure For MCB IP40 (TXM series) Iron Base
Overall panel design is luxury and attractive, the face covering colors are dark green and brawn (provided according to the color needs of the different interior residential designs except for the standard colors). The design of the face covering gives a noble and elegant feeling. lure Ivory, high Strength, never change color.Transparent material is PC. Fixed frame, simple structure, and easy installation. -
SHPN Series Waterproof Distribution Box
High一end distribution box,overall panel design is luxury arid attractive. The material is PC which makes it really resistant ,fireproof and UV protection. Fixed frame, simple structure,and easy to install.It is applicable for special waterproof,dust proof and corrosion-proof locations.Executive standard IEC60529 EN 60309 IP65. -
Plastic Empty Enclosure For MCB IP65 (HT Series) Water Proof Distribution Box
HT Series lighting box is in line with IEC-493-1 standard, attractive and durable,safe and reliable, which is widely used in various places such as factory, mansion,residence, chapping center and so on.