Professional China Plug-In Device And Draw-Out Device - Auxiliary contact Alarm contact – DaDa
Application The auxiliary contacts is intended for automatical controlling of the auxiliary circuit of MCCB,and open action of current,and under voltage of circuit and equipment. Auxiliary And Alarm Contacts Size 1N/O and 1N/C+1alarm contact 2N/O and2N/C+1alarm contact Wiring Diagram Of Auxiliary And Alarm Contacts State of MCCB State of alarm contacts diagram of wiring Close position Explanation Us1 is auxiliary power Us2 is alarm power Open position Explanat... -
Good Quality Residual Current Circuit Breaker - DAB6LE-63 Series Earth Leakage Circuit Breaker(ELCB) – DaDa
Advantages • Compact structure, small size, 2 modules wide. • It has neutral line breaking function, more secure and reliable. • It has dual-purpose terminal with strong connection ability. • It has the contact status indicator, easy to identify the contact condition. • Can be used with a variety of accessories, and used for overvoltage protection. Physical Parameters Of DAB6LE-63 Residual Current Device Standard of conformity: IEC61009 (EN61009) and GB16917.1 Sensitivity: type A, type AC Rel... -
2018 High quality 4 Pole Earth Leakage Circuit Breaker – DAM1L-630 CBR ELCB Earth Leakage Protection Circuit Breaker – DaDa
Introduction DAM1L series residual current (leakage) circuit breaker (hereinafter referred to as circuit breaker) is a new series of residual current (leakage) successfully developed by using international standard design and advanced manufacturing technology. Protected moulded case type circuit breaker. The rated insulation voltage of circuit breakers of this series is 400V (Inm is less than 160A) and 690V (Inm is more than 250A), which is mainly used for ac 50Hz and rated In a power distrib... -
One of Hottest for Auto Circuit Breaker - DAB5 series Miniature Circuit breaker(MCB) – DaDa
>> Introduction DAB5-63 are intended for protecting distribution and group systems having different loads: - electric appliances, lighting – V characteristic switches; - drives with moderate starting currents (compressor, fan group) – C characteristic switches; - drives with high starting currents (hoisting mechanisms, pumps) – D characteristic switches; Miniature circuit breaker DAB5-63 are recommended for use in electrical distribution panels of residential and public bui... -
-
Short Lead Time for 4 Pole Mccb Circuit Breaker - HVS MCB with window – DaDa
Safety Terminals To avoid improper cable termination, the safety terminals guide the cable towards the cage terminal for systematic termination Bi Stable Clip Every device is provided with a dual position DIN rail clip, so it becomes much easier to change a device from a device bank connected to a bus-bar, without disturbing the existing wiring Large Cable Terminals Suitable for copper and aluminum cables, these terminals are compatible with cables upto 35 mm 2 cross section area ... -
-
OEM manufacturer Generator Circuit Breaker - C45 4P Miniature Circuit Breaker – DaDa
Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1... -
Best Price on Type C Circuit Breaker - DAB7 Series Miniature Circuit Breaker(MCB) – DaDa
Advantages • Two types of overcurrent protection – thermal and electromagnetic. • High Breaker capacity 10KA • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Technical Features MCB DAB7-63 For protection of general power distribution (IEC/E... -
China wholesale thermal overload circuit breaker - DAM11 Series Moulded-case Circuit Breaker – DaDa
Product overview DAM11, DAM11LY, DAM11RT, DAM11E and DAM11EY series of circuit breakers are new upgraded circuit breakers researched and developed by the company combined with the advantages of similar international products and demand of domestic and international markets. With insulation voltage up to 1000V, the circuit breaker is applicable for distribution systems of AC50Hz, rated working voltage 690V and rated working current from 10A to 800A, used to distribute electric power energ... -
Factory wholesale 15a Circuit Breaker - DAB7 L7 Mini circuit breaker – DaDa
Product Model Pole Trip type Rated current DAB7-63 1P C 63 1P 2P 3P 4P B:Type B C:Type C D:Type D 1:1A 10:10A 32:32A 2:2A 16:16A 40:40A 3:3A 20:20A 50:50A 4:4A 25:25A 63:63A 6:6A Normal operating conditions and installation conditions ■ Ambient air temperature of L7 6/10KA Miniature Circuit Breaker: -5℃~40℃, and average temperature in 24h below +35℃. ■ Altitude of the installation site should not exceed 2000m. ■ Atmospheric relative humidity at ... -
Professional China Abb Contactor - Contactor – DaDa
Introduction The structure of DA Type’s contactor is compact ;its volume is small;long perfomance life;Working stability and reliability ;installation is easy maintenance .Accessories of auxiliary contacts are plentiful it meet the various different market needs. It is mainly applied to control in motors ,electric line ,code wire ,bypass and lighting etc. of civilian and Industry. The main technical data: Main Circuit Rating Current: 9一370 A Motor power: 4一200KW (400V,AC-3)