Home
About Us
Factory Tour
Process Quality
Profile
Certification
History
Download
Video
FAQs
Product
Moulded Case Circuit Breaker丨MCCB
DAM1 丨MCCB
Fixed Type丨MCCB
Electronic Type 丨MCCB
Thermal And Magnetic Adjustable 丨MCCB
Thermal Adjustable Type 丨MCCB
DAM1 ISOMAX S Series丨MCCB
CM1 丨MCCB
CM1E Electronic 丨MCCB
DAM2 丨MCCB
DAM2 Electronic 丨MCCB
DAM3 丨MCCB
DAM4 丨MCCB DPX
DAM5 丨MCCB 3VL
DAM7 丨MCCB ABE
DAM8 丨MCCB ABN
DAM9 丨MCCB NF
DAM10 丨MCCB NS
Miniature Circuit Breaker丨MCB
NOVA 丨MCB
DAB5-63 丨MCB
DAB6-63 丨MCB
DAB7-63 丨MCB DC
DAB6-100 丨MCB
DAB6丨MCB
BA47-29 MCB
HVS 丨MCB
HVS丨MCB with window
HVS 丨 Isolator
C65丨MCB
DAB7-100 丨MCB
DAB7-125 丨MCB
DAB7-63 丨MCB
DAB7丨MCB L7
C45 丨MCB
MCB Accessory
DAB7N-40 DPN 丨MCB
RCBO
DABF-63 Electromagnetical 丨RCBO
DABL-63 Electronic 丨RCBO
DAB7NL-32 DPN 丨RCBO
ABDT-63 丨RCBO
ELCB丨RCCB
RTF1L-63 丨RCCB
DAB6LE-63 丨RCCB
DAF360 丨RCCB
DAL1-63 丨RCCB
DAL2-63 丨RCCB
DAL3-63 丨RCCB
DAL4-63 丨RCCB
DAL5-63 丨RCCB
DAL6-63 丨RCCB
DAL7-63 丨RCCB
DAL8-63 丨RCCB
DAL9-63 丨RCCB
Dal10-63 丨RCCB
ELCB丨CBR MCCB
DAM1L-125 丨CBR MCCB
DAM1L-160丨CBR MCCB
DAM1L-250丨CBR MCCB
DAM1L-630 丨CBR MCCB
CM1LE 丨CBR MCCB
Air Circuit Breaker丨ACB
Contactor
Motor Protection Circuit Breaker丨MPCB
Modular Distribution Box
MPH Shrinkable Busbar Conjunction Box
Circuit Breaker Accessory
News&Events
Exhibition
Product news
Our Advantage
Contact Us
English
product
Home
Featured
Manufacturer for Residual Circuit Current Breaker - DAL10-63 Residual Current Circuit Breaker(RCCB) – DaDa
Main Parameters Technical parameter parameter valu Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A),...
inquiry
detail
2018 High quality Auxiliary Contact - Electrical Operating Mechanism (Motor) – DaDa
DAM1(ABB) Electrical Operating Mechanism The electrical operating mechanism is available remote close of MCCB The types of electrical operating mechanism are shown in table 2 Types Of Electrical Operating Mechanism: Table 2 Rated current of frame size Inm Types of electrical Operating Mechanism CD1 CD2 CD3 CD 63A - CD2-63 - - 100A - CD2-100 - - 160A - CD2-160 - - 250A CD1-250 CD2-250 - CD-250 400A CD1-400 - - CD-400...
inquiry
detail
Top Suppliers 4 Pole Circuit Breaker - DAB7-125 Series Miniature Circuit Breaker(MCB) – DaDa
Advantages • Trip Free mechanism • High Breaker capacity 15KA • Positive contact indication • Thermal and magnetic trip function • Current limiting design for short circuit fault protection • CE marking,Semko product • Specification:IEC 60947-2 Design Features Large Cable Terminals Suitable for copper and aluminum cables, these terminals are compatible with cables upto 35mm2 cross section area. Technical Features MCB DAB7-125 For protection of general power distribution (IEC/EN 60947-2) ...
inquiry
detail
Factory wholesale 15a Circuit Breaker - DAB6-100 Miniature Circuit Breaker – DaDa
Application DAB6-100 is such features as delicate appearance, light weight, excellent and reliableperformance, high breaking capacity, rapid tripping and mounted by rail. Its enclosure and com-ponents adopts high fire-retarding and shock-resistance plastic of long durability. It mainly servesfor protecting the circuits of AC 50Hz, 230V of single pole, 400V of two poles or three or fourpoles from overload or short-circuit, and also for unfrequent making and breaking electricalapparatus and lig...
inquiry
detail
China wholesale Auxiliary Contact+Alarm Contact - Auxiliary contact Alarm contact – DaDa
Application The auxiliary contacts is intended for automatical controlling of the auxiliary circuit of MCCB,and open action of current,and under voltage of circuit and equipment. Auxiliary And Alarm Contacts Size 1N/O and 1N/C+1alarm contact 2N/O and2N/C+1alarm contact Wiring Diagram Of Auxiliary And Alarm Contacts State of MCCB State of alarm contacts diagram of wiring Close position Explanation Us1 is auxiliary power Us2 is alarm power Open position Explanat...
inquiry
detail
Good Quality Moulded Case Circuit Breaker - DAM1 160 Series MCCB ABB ISOMAX1 – DaDa
Advantages • Easy independent installation of auxiliary devices: Alarm contact; Auxiliary contact; Under voltage release; Shunt release; Handle operating mechanism; Electrical operating mechanism; Plug-in device; Draw-out device;. •Standard set of each circuit breaker consists of connecting busbars or cable lugs, phase separators, a set of screws and nuts for its mounting ontan installation panel. •With the help of special clamp 125 and 160 units can be installed onta DIN-rail. •Weight and di...
inquiry
detail
Renewable Design for Time Delay Circuit Breaker - MCB Shunt Release – DaDa
Installation and Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. 2. The...
inquiry
detail
OEM Supply 2 Pole Circuit Breaker - DAB6 MCB – DaDa
Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa...
inquiry
detail
Good Quality Moulded Case Circuit Breaker - DAM1 160 Series MCCB ABB ISOMAX1 – DaDa
Advantages • Easy independent installation of auxiliary devices: Alarm contact; Auxiliary contact; Under voltage release; Shunt release; Handle operating mechanism; Electrical operating mechanism; Plug-in device; Draw-out device;. •Standard set of each circuit breaker consists of connecting busbars or cable lugs, phase separators, a set of screws and nuts for its mounting ontan installation panel. •With the help of special clamp 125 and 160 units can be installed onta DIN-rail. •Weight and di...
inquiry
detail
Factory wholesale 150 Amp Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa
Technical parameter of DAB7-100 8kA miniature circuit breaker Standard of conformity: IEC60898, GB10963 Rated voltage: 230/400V, 50HZ Rated breaking capacity: 10KA (6-63A), 8KA (80-100A) Protection grade: IP20 Flame retardant grade: grade2 Endurance (power-driven): no less than 8,000 times of opening Endurance (manual operation): no less than 20,000times of opening Mechanical parameters of DAB7-100 8kA miniature circuit breaker Electric wire: 1~35mm2 Connection mode: There are two kinds of co...
inquiry
detail
China Cheap price Thermal Adjustable circuit breaker - DAM1 1600 Series MCCB ABB ISOMAX – DaDa
Advantages • Easy independent installation of auxiliary devices: Alarm contact; Auxiliary contact; Under voltage release; Shunt release; Handle operating mechanism; Electrical operating mechanism; Plug-in device; Draw-out device;. • Standard set of each circuit breaker consists of connecting busbars or cable lugs, phase separators, a set of screws and nuts for its mounting onto an installation panel. • With the help of special clamp 125 and 160 units can be installed onto a DIN-rail. ...
inquiry
detail
China wholesale Distribution Box Iron Base - Plastic Empty Enclosure For MCB IP65 (HT Series) Water Proof Distribution Box – DaDa
Features Panel is the ABS material far the engineering, high strength, never change color, the transparent material is PC. Cover push-type opening and Closing Face covering of the distribution box adopts the push一type opening and closing mode, the face mask can be opened by pressing lightly, the self-locking positioning hinge structure is provided when opening Wiring design of the power distribution box The guide rail support plate can be lifted to the highest movable point, it is no longer ...
inquiry
detail
<<
< Previous
80
81
82
83
84
85
86
Next >
>>
Page 83 / 462
Hit enter to search or ESC to close