High reputation 250 Amp Circuit Breaker - C45 4P Miniature Circuit Breaker – DaDa
Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1... -
Factory Price 3 Amp Circuit Breaker - C45 2P Miniature Circuit Breaker – DaDa
Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1P 2P... -
OEM Supply 2 Pole Circuit Breaker - BA47-29 series Miniature Circuit breaker(MCB) – DaDa
>> Introduction BA47-29 are intended for protecting distribution and group systems having different loads: - electric appliances, lighting – V characteristic switches; - drives with moderate starting currents (compressor, fan group) – C characteristic switches; - drives with high starting currents (hoisting mechanisms, pumps) – D characteristic switches; Miniature circuit breaker BA47-29 are recommended for use in electrical distribution panels of residential and public bui... -
Fast delivery Marine Circuit Breaker - BA47-29 series Miniature Circuit breaker(MCB) – DaDa
>> Introduction BA47-29 are intended for protecting distribution and group systems having different loads: - electric appliances, lighting – V characteristic switches; - drives with moderate starting currents (compressor, fan group) – C characteristic switches; - drives with high starting currents (hoisting mechanisms, pumps) – D characteristic switches; Miniature circuit breaker BA47-29 are recommended for use in electrical distribution panels of residential and public bui... -
China OEM Three Phase Circuit Breaker - DAB5 MCB – DaDa
Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa... -
China Cheap price Plastic Distribution Box - Modular Distribution Box (BE series) – DaDa
Technical Specification Product series: embedded mounting distribution box/surface mountingdistribution box Ways:4way, 7way, 10way, 12way, 14way, 16way, 18way, 20way, 24way(embedded mounting), 28way, 40way Products: 1.embedded mounting BEP-A 104, BEP-A 107, BEP-A 110, BEP-A 112. BEP-A 114, BEP-A 116, BEP-A 118, BEP-A 120, BEP-A124, BEP-A228, BEP-A240 2.surface mounting BEP-M 104, BEP-M 107, BEP-M 110, BEP-M 112, BEP-M 114, BEP-M116, BEP-M 118, BEP-M 120, BEP-M 228, BEP-M 24... -
China Cheap price Ac Contactor Switch - Contactor – DaDa
Introduction The structure of DA Type’s contactor is compact ;its volume is small;long perfomance life;Working stability and reliability ;installation is easy maintenance .Accessories of auxiliary contacts are plentiful it meet the various different market needs. It is mainly applied to control in motors ,electric line ,code wire ,bypass and lighting etc. of civilian and Industry. The main technical data: Main Circuit Rating Current: 9一370 A Motor power: 4一200KW (400V,AC-3) -
OEM/ODM Supplier Solar Circuit Breaker - MCB Under Voltage Release – DaDa
Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. ... -
2018 wholesale price Under Voltage Release - Auxiliary Contacts – DaDa
Application The auxiliary contacts is intended for automatical controlling of the auxiliary circuit of MCCB,such as indication of the open and close states of MCCB. Auxiliary Contacts Size 1N/O and 1N/C 2N/O and2N/C 4N/O and 4N/C Wiring Diagram Of Auxiliary Contacts State of MCCB State ofauxiliary contacts diagram of wiring Close position 1 set of auxiliary contacts,but2 sets of contacts to be supplied For Inm=63A-225A 2 set of auxiliary contacts,but4 sets... -
Fast delivery Marine Circuit Breaker - DAB7N-40 Series DPN Miniature Circuit Breaker(MCB) – DaDa
Advantages • Two types of overcurrent protection – thermal and electromagnetic. • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Electrical Parameters of DAB7N-40 Min iature Circuit Breaker Standard of conformity: IEC60898, GB10963 Rated power: ... -
-