China Cheap price Elctronic Rccb - DAL8-63 Residual Current Circuit Breaker(RCCB) – DaDa
Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(... -
-
Super Lowest Price Earth Circuit Breaker - DAB6-100 Miniature Circuit Breaker – DaDa
Application DAB6-100 is such features as delicate appearance, light weight, excellent and reliableperformance, high breaking capacity, rapid tripping and mounted by rail. Its enclosure and com-ponents adopts high fire-retarding and shock-resistance plastic of long durability. It mainly servesfor protecting the circuits of AC 50Hz, 230V of single pole, 400V of two poles or three or fourpoles from overload or short-circuit, and also for unfrequent making and breaking electricalapparatus and lig... -
2018 Good Quality House circuit breaker - DAB5 MCB – DaDa
Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa... -
High Quality Rcbo Circuit Breaker - RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection – DaDa
Introduction Residual current operated circuit breakers with overcurrent protection ABDT-63 are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection. They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting. -
Good Quality Motor Protection Circuit Breaker - GV-M Motor Protection Circuit Breaker – DaDa
Application GV series motor protection circuit breaker are mainly used fo the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A) ... -
China Cheap price Miniature circuit breaker - MCB Shunt Release – DaDa
Installation and Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. 2. The... -
China wholesale 1p 2p 3p 4p Mcb - MCB Under Voltage Release – DaDa
Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. ... -
Good Quality Contactor - Contactor – DaDa
Introduction The structure of DA Type’s contactor is compact ;its volume is small;long perfomance life;Working stability and reliability ;installation is easy maintenance .Accessories of auxiliary contacts are plentiful it meet the various different market needs. It is mainly applied to control in motors ,electric line ,code wire ,bypass and lighting etc. of civilian and Industry. The main technical data: Main Circuit Rating Current: 9一370 A Motor power: 4一200KW (400V,AC-3) -
Super Purchasing for 16 Amp Rcd Circuit Breaker - Micro changeover switch – DaDa
l. Applicable range SF series DIN-rail installation micro change-over switch is a kind of switch apparatus applicabl to the hybrid resistance and impedance circuit with AC 50Hz or 60Hz, rated voltage below 230-400V andrated current16A-125A, allowing for 2 power sources or load conversion,realizing the functions of circuit conversion andswitch disconnection. It can be used for the changeover of power supply of electrical equipments,changeover of positiveand reverse running of motor, measuremen... -
Renewable Design for Time Delay Circuit Breaker - DAB6-100 Miniature Circuit Breaker – DaDa
Application DAB6-100 is such features as delicate appearance, light weight, excellent and reliableperformance, high breaking capacity, rapid tripping and mounted by rail. Its enclosure and com-ponents adopts high fire-retarding and shock-resistance plastic of long durability. It mainly servesfor protecting the circuits of AC 50Hz, 230V of single pole, 400V of two poles or three or fourpoles from overload or short-circuit, and also for unfrequent making and breaking electricalapparatus and lig... -
Professional China A Type Ac Type Rcbo - DABL-63 RCBO 6KA Residual Current Operated Circuit Breaker – DaDa
Advantages • Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series. • The most subtle electric shock hazard protection in case of direct contact with conducting parts. • Independent contact position indicator. • Wide range of operating temperatures from –25 to +40° С. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. • “TEST”button for checking the ...