  • China wholesale F360 Rccb - DAL3-63 Residual Current Circuit Breaker(RCCB) – DaDa

    China wholesale F360 Rccb - DAL3-63 Residual Current Circuit Breaker(RCCB) – DaDa

    Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)...
  • Hot sale Two Pole Circuit Breaker - DAB6-63 with transparent cover series miniature circuit breaker – DaDa
  • Short Lead Time for 4 Pole Mccb Circuit Breaker - DAB7-63 Nova Series Miniature Circuit Breaker(MCB) – DaDa

    Short Lead Time for 4 Pole Mccb Circuit Breaker - DAB7-63 Nova Series Miniature Circuit Breaker(MCB) – DaDa

    Advantages • Two types of overcurrent protection – thermal and electromagnetic. • High Breaker capacity 6/10KA • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Technical Features MCB DAB7-63 For protection of general power distribution (IEC/...
  • China Cheap price Ac Contactor Switch - Contactor – DaDa

    China Cheap price Ac Contactor Switch - Contactor – DaDa

    Introduction The structure of DA Type’s contactor is compact ;its volume is small;long perfomance life;Working stability and reliability ;installation is easy maintenance .Accessories of auxiliary contacts are plentiful it meet the various different market needs. It is mainly applied to control in motors ,electric line ,code wire ,bypass and lighting etc. of civilian and Industry. The main technical data: Main Circuit Rating Current: 9一370 A Motor power: 4一200KW (400V,AC-3)
  • Wholesale Micro Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa

    Wholesale Micro Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa

    Technical parameter of DAB7-100 8kA miniature circuit breaker Standard of conformity: IEC60898, GB10963 Rated voltage: 230/400V, 50HZ Rated breaking capacity: 10KA (6-63A), 8KA (80-100A) Protection grade: IP20 Flame retardant grade: grade2 Endurance (power-driven): no less than 8,000 times of opening Endurance (manual operation): no less than 20,000times of opening Mechanical parameters of DAB7-100 8kA miniature circuit breaker Electric wire: 1~35mm2 Connection mode: There are two kinds of co...
  • Good Quality Mini Circuit Breaker - C65 MCB – DaDa

    Good Quality Mini Circuit Breaker - C65 MCB – DaDa

    ■ Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A ■ Rated working voltage: 110V, 230V ~ (1P, 1P + N), 400V ~ (2 ~ 4P, 3P + N) ■ Isolation □ Mechanical contact indication window, realistic cut-off instructions □ The window is green and the contact is in the open state. The window is red and the contact is in the closed state ■ Impulse withstand voltage: 4kV ■ Max withstand current: 6kA Circuit Breaker ■ Mechanical life: 20,000 times ■ Electrical life: 10000 times ■ Am...
  • China Cheap price Electrical Operating Mechanism(Motor) - Plug-In And Draw-Out Device – DaDa

    China Cheap price Electrical Operating Mechanism(Motor) - Plug-In And Draw-Out Device – DaDa

     CM 1 Plug-in Version Accessory Type Scope of application Specification and quantities Contact pin Arc-isolation plate and quantities Plug-in version install using hexagonal screw and quantities Circuit breaker install using screw and quantities Contact pin fixed screw and quantities User bind the board install using screw and quantities 63 Type plug-in version CM1-63,NM1-63,CDM1-63,TM30-63 1 6 4 4-M6X23 4-M3X18 6-M5copper nut 6-M5X10 100 Type plug-...
  • 2018 wholesale price Dc Rated Contactor - Contactor – DaDa

    2018 wholesale price Dc Rated Contactor - Contactor – DaDa

    Introduction The structure of DA Type’s contactor is compact ;its volume is small;long perfomance life;Working stability and reliability ;installation is easy maintenance .Accessories of auxiliary contacts are plentiful it meet the various different market needs. It is mainly applied to control in motors ,electric line ,code wire ,bypass and lighting etc. of civilian and Industry. The main technical data: Main Circuit Rating Current: 9一370 A Motor power: 4一200KW (400V,AC-3)
  • China wholesale F360 Rccb - DAL6-63 Residual Current Circuit Breaker(RCCB) – DaDa

    China wholesale F360 Rccb - DAL6-63 Residual Current Circuit Breaker(RCCB) – DaDa

    Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)...
  • China wholesale Mccb With Earth Leakage Protection - DAM1L Series Earth Leakage protection Circuit Breaker (ELCB) – DaDa

    China wholesale Mccb With Earth Leakage Protection - DAM1L Series Earth Leakage protection Circuit Breaker (ELCB) – DaDa

    Under normal conditions,It can also be used for infrequent switching of lines. This circuit breaker also has the following protection: • It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection. • Provide protection against the danger of increasing ground voltage due to insulation damage; • Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection. • Circuit breaker...
  • 2018 High quality Contactor Switch Ac - Contactor – DaDa

    2018 High quality Contactor Switch Ac - Contactor – DaDa

    Introduction The structure of DA Type’s contactor is compact ;its volume is small;long perfomance life;Working stability and reliability ;installation is easy maintenance .Accessories of auxiliary contacts are plentiful it meet the various different market needs. It is mainly applied to control in motors ,electric line ,code wire ,bypass and lighting etc. of civilian and Industry. The main technical data: Main Circuit Rating Current: 9一370 A Motor power: 4一200KW (400V,AC-3)
  • Wholesale Dealers of 2 Amp Circuit Breaker - DAB5 MCB – DaDa

    Wholesale Dealers of 2 Amp Circuit Breaker - DAB5 MCB – DaDa

    Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa...