Home
About Us
Factory Tour
Process Quality
Profile
Certification
History
Download
Video
FAQs
Product
Moulded Case Circuit Breaker丨MCCB
DAM1 丨MCCB
Fixed Type丨MCCB
Electronic Type 丨MCCB
Thermal And Magnetic Adjustable 丨MCCB
Thermal Adjustable Type 丨MCCB
DAM1 ISOMAX S Series丨MCCB
CM1 丨MCCB
CM1E Electronic 丨MCCB
DAM2 丨MCCB
DAM2 Electronic 丨MCCB
DAM3 丨MCCB
DAM4 丨MCCB DPX
DAM5 丨MCCB 3VL
DAM7 丨MCCB ABE
DAM8 丨MCCB ABN
DAM9 丨MCCB NF
DAM10 丨MCCB NS
Miniature Circuit Breaker丨MCB
NOVA 丨MCB
DAB5-63 丨MCB
DAB6-63 丨MCB
DAB7-63 丨MCB DC
DAB6-100 丨MCB
DAB6丨MCB
BA47-29 MCB
HVS 丨MCB
HVS丨MCB with window
HVS 丨 Isolator
C65丨MCB
DAB7-100 丨MCB
DAB7-125 丨MCB
DAB7-63 丨MCB
DAB7丨MCB L7
C45 丨MCB
MCB Accessory
DAB7N-40 DPN 丨MCB
RCBO
DABF-63 Electromagnetical 丨RCBO
DABL-63 Electronic 丨RCBO
DAB7NL-32 DPN 丨RCBO
ABDT-63 丨RCBO
ELCB丨RCCB
RTF1L-63 丨RCCB
DAB6LE-63 丨RCCB
DAF360 丨RCCB
DAL1-63 丨RCCB
DAL2-63 丨RCCB
DAL3-63 丨RCCB
DAL4-63 丨RCCB
DAL5-63 丨RCCB
DAL6-63 丨RCCB
DAL7-63 丨RCCB
DAL8-63 丨RCCB
DAL9-63 丨RCCB
Dal10-63 丨RCCB
ELCB丨CBR MCCB
DAM1L-125 丨CBR MCCB
DAM1L-160丨CBR MCCB
DAM1L-250丨CBR MCCB
DAM1L-630 丨CBR MCCB
CM1LE 丨CBR MCCB
Air Circuit Breaker丨ACB
Contactor
Motor Protection Circuit Breaker丨MPCB
Modular Distribution Box
MPH Shrinkable Busbar Conjunction Box
Circuit Breaker Accessory
News&Events
Exhibition
Product news
Our Advantage
Contact Us
English
product
Home
Featured
2018 wholesale price thermal protection circuit breaker - DAM1 400 MCCB Moulded Case Circuit Breaker – DaDa
Thermal-Magnetic Circuit Breakers Thermal protection function:(For protection under over load conditions) Bimetal, which provides thermal protection, consists of combination of two metals with different extension coefficients under heat. When bimetal is heated, it bends towards the metal with less extension. In this way, a notch that assists opening of the breaker mechanism is released to disable the breaker. Bending speed of bimetal is in direct proportion with size of the current passing t...
inquiry
detail
Factory Price 3 Amp Circuit Breaker - C45 2P Miniature Circuit Breaker – DaDa
Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1P 2P...
inquiry
detail
2018 wholesale price Motor Protection Circuit – GV-M Motor Protection Circuit Breaker – DaDa
Application GV series motor protection circuit breaker are mainly used fo the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A) ...
inquiry
detail
Wholesale Dealers of 2 Amp Circuit Breaker - DAB6-100 Miniature Circuit Breaker – DaDa
Application DAB6-100 is such features as delicate appearance, light weight, excellent and reliableperformance, high breaking capacity, rapid tripping and mounted by rail. Its enclosure and com-ponents adopts high fire-retarding and shock-resistance plastic of long durability. It mainly servesfor protecting the circuits of AC 50Hz, 230V of single pole, 400V of two poles or three or fourpoles from overload or short-circuit, and also for unfrequent making and breaking electricalapparatus and lig...
inquiry
detail
OEM/ODM Factory 100 Amp Circuit Breaker - C45 4P Miniature Circuit Breaker – DaDa
Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1...
inquiry
detail
Newly Arrival Residual Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa
Technical parameter of DAB7-100 8kA miniature circuit breaker Standard of conformity: IEC60898, GB10963 Rated voltage: 230/400V, 50HZ Rated breaking capacity: 10KA (6-63A), 8KA (80-100A) Protection grade: IP20 Flame retardant grade: grade2 Endurance (power-driven): no less than 8,000 times of opening Endurance (manual operation): no less than 20,000times of opening Mechanical parameters of DAB7-100 8kA miniature circuit breaker Electric wire: 1~35mm2 Connection mode: There are two kinds of co...
inquiry
detail
Professional Design 10 Amp Mini Circuit Breaker - C45 2P Miniature Circuit Breaker – DaDa
Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1P 2P...
inquiry
detail
New Arrival China 10 Amp Mini Circuit Breaker - MCB Under Voltage Release – DaDa
Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. ...
inquiry
detail
Hot New Products Tp Mccb - DAM3-630 MCCB Molded Case Circuit Breaker – DaDa
Overview The rated current of DAM3-630 molded case circuit breaker can reach up to 630A. These electrical devices are suitable for the protection of power distribution circuits with an alternating current of 50-60Hz and a rated operating current up to 1000A. They can also be used in electric motors for infrequent starting and overload protection as well as protection against short circuiting and undervoltage conditions. The circuit breakers feature the characteristics of small volume, high br...
inquiry
detail
Competitive Price for 400 Amp Circuit Breaker - DAB7N-40 Series DPN Miniature Circuit Breaker(MCB) – DaDa
Advantages • Two types of overcurrent protection – thermal and electromagnetic. • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Electrical Parameters of DAB7N-40 Min iature Circuit Breaker Standard of conformity: IEC60898, GB10963 Rated power: ...
inquiry
detail
Free sample for Automatic Circuit Breaker - MCB Under Voltage Release – DaDa
Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. ...
inquiry
detail
Free sample for Automatic Circuit Breaker - C45 1P Miniature Circuit Breaker – DaDa
Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1P...
inquiry
detail
<<
< Previous
392
393
394
395
396
397
398
Next >
>>
Page 395 / 472
Hit enter to search or ESC to close