-
Good Quality Thermal Shrink Busbar Box - MPH Series Busbar Conjunction Box (Heat Shrink Junction Box) 1kv10kv35kv – DaDa
Application Main busbar connector box in the electrical equipment at the electrical connection of the insulation protection, and high and low voltage switchgear circuit breakers are not deformed, heat is not deformed, heat does not shrink, the appearance of the corners, wall thickness Uniform, accurate size, stable performance, smooth and meticulous appearance, long service life, etc., can better highlight the equipment grade, the overall effect is more obvious for our company’s product... -
Professional China Id Rccb - DAL5-63 Residual Current Circuit Breaker(RCCB) – DaDa
Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)... -
Chinese Professional 20 Amp Mini Circuit Breaker - MCB Under Voltage Release – DaDa
Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. ... -
Manufacturer for 10a Mccb - DAM9 Molded Case Circuit Breaker(NF-CP) – DaDa
Application The DAM9 NF-CP series Molded case circuit breaker type (hereafter to as circuit breaker), advanced design,Is this company uses the international one of the technique of manufacture development, development new circuit breakers Its fixed isolation voltage is 690V, is suitable in exchanges 50Hz, fixed working voltage 400V and below.Rated current to 630A circuit as frequent changeover gum less frequent motor starter. The Circuit breaker with overload,short circuit protection device... -
High Quality Rotary Handle Mechanism - Auxiliary contact Alarm contact – DaDa
Application The auxiliary contacts is intended for automatical controlling of the auxiliary circuit of MCCB,and open action of current,and under voltage of circuit and equipment. Auxiliary And Alarm Contacts Size 1N/O and 1N/C+1alarm contact 2N/O and2N/C+1alarm contact Wiring Diagram Of Auxiliary And Alarm Contacts State of MCCB State of alarm contacts diagram of wiring Close position Explanation Us1 is auxiliary power Us2 is alarm power Open position Explanat... -
High Quality for 1 Pole Circuit Breaker - MCB Under Voltage Release – DaDa
Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. ... -
Hot New Products Contact Auxiliary – Auxiliary contact Alarm contact – DaDa
Application The auxiliary contacts is intended for automatical controlling of the auxiliary circuit of MCCB,and open action of current,and under voltage of circuit and equipment. Auxiliary And Alarm Contacts Size 1N/O and 1N/C+1alarm contact 2N/O and2N/C+1alarm contact Wiring Diagram Of Auxiliary And Alarm Contacts State of MCCB State of alarm contacts diagram of wiring Close position Explanation Us1 is auxiliary power Us2 is alarm power Open position Explanat... -
2018 Good Quality Rccb Protection - DAL2-63 Residual Current Circuit Breaker(RCCB) – DaDa
Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)... -
18 Years Factory Short Circuit Breaker - DAB6 Series Miniature Circuit Breaker(MCB) – DaDa
Advantages • Two types of short circuit protection. • Wide range of operating temperatures from –40 to +50° С. • Updated wider engagement lever with improved contact area. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. MCB DAB6-63 For protection of general power distribution (IEC/EN 60898-1) Poles 1P 2P 3P 4P Electrical performance Functions short circuit protection,overload protection,isolationg,co... -
Bottom price 60 Amp Circuit Breaker - DAB7 Series Miniature Circuit Breaker(MCB) – DaDa
Advantages • Two types of overcurrent protection – thermal and electromagnetic. • High Breaker capacity 10KA • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Technical Features MCB DAB7-63 For protection of general power distribution (IEC/E... -
Professional China Plug-In Device And Draw-Out Device - Shunt Release – DaDa
The shunt release is intended for remote controlling of opera of MCCB Release instantaneous duty. Characteristics of Shunt release: Electricalaccessories Shunt release Range ofsupply voltage (0.7-1.1)) x Us Rated controlsupply voltage us Power supply AC 50Hz 220V 380V Power loss 150V 150V DC 110V 220V Power loss 150V Wiring diagram of Shunt release: SB2- Opening Push-putton(ready by user ) P3,P4- Terminal number Us- Control power QF -Au... -
Professional China 10KA MCB - C45 4P Miniature Circuit Breaker – DaDa
Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1...