Home
About Us
Factory Tour
Process Quality
Profile
Certification
History
Download
Video
FAQs
Product
Moulded Case Circuit Breaker丨MCCB
DAM1 丨MCCB
Fixed Type丨MCCB
Electronic Type 丨MCCB
Thermal And Magnetic Adjustable 丨MCCB
Thermal Adjustable Type 丨MCCB
DAM1 ISOMAX S Series丨MCCB
CM1 丨MCCB
CM1E Electronic 丨MCCB
DAM2 丨MCCB
DAM2 Electronic 丨MCCB
DAM3 丨MCCB
DAM4 丨MCCB DPX
DAM5 丨MCCB 3VL
DAM7 丨MCCB ABE
DAM8 丨MCCB ABN
DAM9 丨MCCB NF
DAM10 丨MCCB NS
Miniature Circuit Breaker丨MCB
NOVA 丨MCB
DAB5-63 丨MCB
DAB6-63 丨MCB
DAB7-63 丨MCB DC
DAB6-100 丨MCB
DAB6丨MCB
BA47-29 MCB
HVS 丨MCB
HVS丨MCB with window
HVS 丨 Isolator
C65丨MCB
DAB7-100 丨MCB
DAB7-125 丨MCB
DAB7-63 丨MCB
DAB7丨MCB L7
C45 丨MCB
MCB Accessory
DAB7N-40 DPN 丨MCB
RCBO
DABF-63 Electromagnetical 丨RCBO
DABL-63 Electronic 丨RCBO
DAB7NL-32 DPN 丨RCBO
ABDT-63 丨RCBO
ELCB丨RCCB
RTF1L-63 丨RCCB
DAB6LE-63 丨RCCB
DAF360 丨RCCB
DAL1-63 丨RCCB
DAL2-63 丨RCCB
DAL3-63 丨RCCB
DAL4-63 丨RCCB
DAL5-63 丨RCCB
DAL6-63 丨RCCB
DAL7-63 丨RCCB
DAL8-63 丨RCCB
DAL9-63 丨RCCB
Dal10-63 丨RCCB
ELCB丨CBR MCCB
DAM1L-125 丨CBR MCCB
DAM1L-160丨CBR MCCB
DAM1L-250丨CBR MCCB
DAM1L-630 丨CBR MCCB
CM1LE 丨CBR MCCB
Air Circuit Breaker丨ACB
Contactor
Motor Protection Circuit Breaker丨MPCB
Modular Distribution Box
MPH Shrinkable Busbar Conjunction Box
Circuit Breaker Accessory
News&Events
Exhibition
Product news
Our Advantage
Contact Us
English
product
Home
Featured
High Quality Rccb Circuit Breaker - RTF1L-63 Residual Current Circuit Breaker(RCCB) – DaDa
Advantage Specification Frame class 63A Rated working voltage 240/415V Rated frequency 50/60Hz Rated working current 16, 20, 25, 32, 40, 50, 63A Rated residual operating current 0.03, 0.1, 0.3A Rated residual un-operating current 0.015, 0.05, 0.15A Sensibility AC Type, A Type, B Type Maximum operating time IΔn t≤0.1s, 5IΔn t≤0.04 Rated making and breaking capacity In≤50A 500A, In=63A 630A Limiting value of un-operating current 6In Rated limiting short-circuit curre...
inquiry
detail
Professional China Motor Start Circuit Breaker - GV-M Motor Protection Circuit Breaker – DaDa
Application GV series motor protection circuit breaker are mainly used fo the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A) ...
inquiry
detail
Good Quality Earth Leakage Circuit Breaker - DAM1L Series Earth Leakage protection Circuit Breaker (ELCB) – DaDa
Under normal conditions,It can also be used for infrequent switching of lines. This circuit breaker also has the following protection: • It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection. • Provide protection against the danger of increasing ground voltage due to insulation damage; • Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection. • Circuit breaker...
inquiry
detail
China wholesale Distribution Box Iron Base - MCB Enclosure (HAG series) – DaDa
Technique parameter Distribution box rated current: 1 way to 4 way:50A 6 way to 18 way:63A Material Insutation: Fire-proof type refractory material Color: Whitie color standard: accord with IEC X40439-3 Protective Degree IEC60529: IP30 Fire-resistant andanomaly heat abiliy IEC60529-1 standard,650C/30sec Compositian,structure. Removable matte blocks to increase the poles. The removable various size holes are available on the box of up and down,bott...
inquiry
detail
2018 wholesale price Rccb - DAL3-63 Residual Current Circuit Breaker(RCCB) – DaDa
Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)...
inquiry
detail
Factory Cheap Hot mccb - DAM1 1600 electronic type Moulded case circuit breaker(MCCB) – DaDa
Advantages • Wide range:100A to 1600A(AC) • Compact dimensions • Adjustable thermal setting(40-100%)In. • Adjustable magnetic setting(1.5-12times)In. • Push to trip button provision. • Separate main and arcing contacts • Wide range of accessories. Electronic Release Characteristic Curve Electronic Release(Electronic Trip Unit) Physical Parameters Of Dam1 Mccb Molded Case Circuit Breaker Category (EN 60947-2/IEC 60947-2) Endurance Model Pole Dielectric Pro...
inquiry
detail
Chinese wholesale Rcbo Protection - DABL-63 RCBO 6KA Residual Current Operated Circuit Breaker – DaDa
Advantages • Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series. • The most subtle electric shock hazard protection in case of direct contact with conducting parts. • Independent contact position indicator. • Wide range of operating temperatures from –25 to +40° С. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. • “TEST”button for checking the ...
inquiry
detail
Trending Products Air Break Circuit Breaker - BA47-29 series Miniature Circuit breaker(MCB) – DaDa
>> Introduction BA47-29 are intended for protecting distribution and group systems having different loads: - electric appliances, lighting – V characteristic switches; - drives with moderate starting currents (compressor, fan group) – C characteristic switches; - drives with high starting currents (hoisting mechanisms, pumps) – D characteristic switches; Miniature circuit breaker BA47-29 are recommended for use in electrical distribution panels of residential and public bui...
inquiry
detail
High Quality Mpcb Circuit Breaker - GV-M Motor Protection Circuit Breaker – DaDa
Application GV series motor protection circuit breaker are mainly used fo the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A) ...
inquiry
detail
China wholesale Mccb With Earth Leakage Protection - DAM1 -160L ELCB Earth Leakage protection circuit breaker1 – DaDa
This circuit breaker also has the following protection: • It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection. • Provide protection against the danger of increasing ground voltage due to insulation damage; • Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection. • Circuit breakers with rated current of 500A and below can also be used for infrequent start, br...
inquiry
detail
Good quality 300 Amp Circuit Breaker - HVS MCB with window – DaDa
Safety Terminals To avoid improper cable termination, the safety terminals guide the cable towards the cage terminal for systematic termination Bi Stable Clip Every device is provided with a dual position DIN rail clip, so it becomes much easier to change a device from a device bank connected to a bus-bar, without disturbing the existing wiring Large Cable Terminals Suitable for copper and aluminum cables, these terminals are compatible with cables upto 35 mm 2 cross section area ...
inquiry
detail
2018 wholesale price Under Voltage Release - Alarm Contacts – DaDa
Alarm Contacts Application The alarm contacts is used for alarm open action of current ,and under voltage of circuit and equipment. Alarm contacts size: 1N/O and 1N/C Wiring Diagram Of Auxiliary Contacts: State of MCCB State of alarm contacts diagram of wiring Close position Open position DAM1-125/160BC DAM1(ABB)-125,160A DAM1-250/400BCDAM1(ABB)-250A,400A DZ20-100BCDZ20-100A DZ20-225BC DZ20-225A ...
inquiry
detail
<<
< Previous
1
2
3
4
5
6
Next >
>>
Page 3 / 477
Hit enter to search or ESC to close