Home
About Us
Factory Tour
Process Quality
Profile
Certification
History
Download
Video
FAQs
Product
Moulded Case Circuit Breaker丨MCCB
DAM1 丨MCCB
Fixed Type丨MCCB
Electronic Type 丨MCCB
Thermal And Magnetic Adjustable 丨MCCB
Thermal Adjustable Type 丨MCCB
DAM1 ISOMAX S Series丨MCCB
CM1 丨MCCB
CM1E Electronic 丨MCCB
DAM2 丨MCCB
DAM2 Electronic 丨MCCB
DAM3 丨MCCB
DAM4 丨MCCB DPX
DAM5 丨MCCB 3VL
DAM7 丨MCCB ABE
DAM8 丨MCCB ABN
DAM9 丨MCCB NF
DAM10 丨MCCB NS
Miniature Circuit Breaker丨MCB
NOVA 丨MCB
DAB5-63 丨MCB
DAB6-63 丨MCB
DAB7-63 丨MCB DC
DAB6-100 丨MCB
DAB6丨MCB
BA47-29 MCB
HVS 丨MCB
HVS丨MCB with window
HVS 丨 Isolator
C65丨MCB
DAB7-100 丨MCB
DAB7-125 丨MCB
DAB7-63 丨MCB
DAB7丨MCB L7
C45 丨MCB
MCB Accessory
DAB7N-40 DPN 丨MCB
RCBO
DABF-63 Electromagnetical 丨RCBO
DABL-63 Electronic 丨RCBO
DAB7NL-32 DPN 丨RCBO
ABDT-63 丨RCBO
ELCB丨RCCB
RTF1L-63 丨RCCB
DAB6LE-63 丨RCCB
DAF360 丨RCCB
DAL1-63 丨RCCB
DAL2-63 丨RCCB
DAL3-63 丨RCCB
DAL4-63 丨RCCB
DAL5-63 丨RCCB
DAL6-63 丨RCCB
DAL7-63 丨RCCB
DAL8-63 丨RCCB
DAL9-63 丨RCCB
Dal10-63 丨RCCB
ELCB丨CBR MCCB
DAM1L-125 丨CBR MCCB
DAM1L-160丨CBR MCCB
DAM1L-250丨CBR MCCB
DAM1L-630 丨CBR MCCB
CM1LE 丨CBR MCCB
Air Circuit Breaker丨ACB
Contactor
Motor Protection Circuit Breaker丨MPCB
Modular Distribution Box
MPH Shrinkable Busbar Conjunction Box
Circuit Breaker Accessory
News&Events
Exhibition
Product news
Our Advantage
Contact Us
English
product
Home
Featured
China wholesale Mccb With Earth Leakage Protection - DAM1L-630 CBR ELCB Earth Leakage Protection Circuit Breaker – DaDa
Introduction DAM1L series residual current (leakage) circuit breaker (hereinafter referred to as circuit breaker) is a new series of residual current (leakage) successfully developed by using international standard design and advanced manufacturing technology. Protected moulded case type circuit breaker. The rated insulation voltage of circuit breakers of this series is 400V (Inm is less than 160A) and 690V (Inm is more than 250A), which is mainly used for ac 50Hz and rated In a power distrib...
inquiry
detail
2018 High quality Small circuit breaker - DAB6 MCB – DaDa
Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa...
inquiry
detail
OEM/ODM Factory 100 Amp Circuit Breaker - MCB Under Voltage Release – DaDa
Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. ...
inquiry
detail
2018 High quality 25 Amp Rcbo - DAB7LN-40 series DPN Residual Current Operation Circuit Breaker(RCBO) – DaDa
Installation method: Using 35mm guide rail according to IEC standard Terminal type: Dual-purpose terminal can be connected to the bus bar and conductor. Terminal connection ability: conductor 1-25mm2, bus bar thickness 0.8-2mm Guide rail: DIN35guide rail Functions of DAB7LN-40 residual current circuit breaker Short circuit protection, overload protection and isolation. Electrical Parameters of DAB7LN-40 Residual Current Circuit Breaker Number of poles 1P+N(18mm) Rated frequency 50-60H...
inquiry
detail
2018 High quality Electromagnetic Rccb - DAB6LE-63 Series Earth Leakage Circuit Breaker(ELCB) – DaDa
Advantages • Compact structure, small size, 2 modules wide. • It has neutral line breaking function, more secure and reliable. • It has dual-purpose terminal with strong connection ability. • It has the contact status indicator, easy to identify the contact condition. • Can be used with a variety of accessories, and used for overvoltage protection. Physical Parameters Of DAB6LE-63 Residual Current Device Standard of conformity: IEC61009 (EN61009) and GB16917.1 Sensitivity: type A, type AC Rel...
inquiry
detail
Professional China Id Rccb - RTF1L-63 Residual Current Circuit Breaker(RCCB) – DaDa
Advantage Specification Frame class 63A Rated working voltage 240/415V Rated frequency 50/60Hz Rated working current 16, 20, 25, 32, 40, 50, 63A Rated residual operating current 0.03, 0.1, 0.3A Rated residual un-operating current 0.015, 0.05, 0.15A Sensibility AC Type, A Type, B Type Maximum operating time IΔn t≤0.1s, 5IΔn t≤0.04 Rated making and breaking capacity In≤50A 500A, In=63A 630A Limiting value of un-operating current 6In Rated limiting short-circuit curre...
inquiry
detail
Hot Selling for Main Switch Circuit Breaker - DAB7-63 DC miniature Circuit Breaker – DaDa
inquiry
detail
China Cheap price 6 Amp Rcbo - DAB7LN-40 series DPN Residual Current Operation Circuit Breaker(RCBO) – DaDa
Installation method: Using 35mm guide rail according to IEC standard Terminal type: Dual-purpose terminal can be connected to the bus bar and conductor. Terminal connection ability: conductor 1-25mm2, bus bar thickness 0.8-2mm Guide rail: DIN35guide rail Functions of DAB7LN-40 residual current circuit breaker Short circuit protection, overload protection and isolation. Electrical Parameters of DAB7LN-40 Residual Current Circuit Breaker Number of poles 1P+N(18mm) Rated frequency 50-60H...
inquiry
detail
Hot New Products Contact Auxiliary – Alarm Contacts – DaDa
Alarm Contacts Application The alarm contacts is used for alarm open action of current ,and under voltage of circuit and equipment. Alarm contacts size: 1N/O and 1N/C Wiring Diagram Of Auxiliary Contacts: State of MCCB State of alarm contacts diagram of wiring Close position Open position DAM1-125/160BC DAM1(ABB)-125,160A DAM1-250/400BCDAM1(ABB)-250A,400A DZ20-100BCDZ20-100A DZ20-225BC DZ20-225A ...
inquiry
detail
High Quality Electronic Mccb - DAM1 Series Thermal Overload Operation Moulded Case Circuit Breaker(Fixed type) – DaDa
Thermal-Magnetic Circuit Breakers Thermal protection function:(For protection under over load conditions) Bimetal, which provides thermal protection, consists of combination of two metals with different extension coefficients under heat. When bimetal is heated, it bends towards the metal with less extension. In this way, a notch that assists opening of the breaker mechanism is released to disable the breaker. Bending speed of bimetal is in direct proportion with size of the current passing t...
inquiry
detail
18 Years Factory Short Circuit Breaker - DAB7N-40 Series DPN Miniature Circuit Breaker(MCB) – DaDa
Advantages • Two types of overcurrent protection – thermal and electromagnetic. • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Electrical Parameters of DAB7N-40 Min iature Circuit Breaker Standard of conformity: IEC60898, GB10963 Rated power: ...
inquiry
detail
Hot New Products Contact Auxiliary – Alarm Contacts – DaDa
Alarm Contacts Application The alarm contacts is used for alarm open action of current ,and under voltage of circuit and equipment. Alarm contacts size: 1N/O and 1N/C Wiring Diagram Of Auxiliary Contacts: State of MCCB State of alarm contacts diagram of wiring Close position Open position DAM1-125/160BC DAM1(ABB)-125,160A DAM1-250/400BCDAM1(ABB)-250A,400A DZ20-100BCDZ20-100A DZ20-225BC DZ20-225A ...
inquiry
detail
<<
< Previous
26
27
28
29
30
31
32
Next >
>>
Page 29 / 477
Hit enter to search or ESC to close