2018 High quality Motor Rated Breaker - GV-M Motor Protection Circuit Breaker – DaDa
Application GV series motor protection circuit breaker are mainly used fo the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A) ... -
Manufacturer for Mcb Breaker - MCB Under Voltage Release – DaDa
Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. ... -
2018 Good Quality Mccb 100 - DAM1 400 MCCB Moulded Case Circuit Breaker – DaDa
Thermal-Magnetic Circuit Breakers Thermal protection function:(For protection under over load conditions) Bimetal, which provides thermal protection, consists of combination of two metals with different extension coefficients under heat. When bimetal is heated, it bends towards the metal with less extension. In this way, a notch that assists opening of the breaker mechanism is released to disable the breaker. Bending speed of bimetal is in direct proportion with size of the current passing t... -
Professional China Plug-In Device And Draw-Out Device - Alarm Contacts – DaDa
Alarm Contacts Application The alarm contacts is used for alarm open action of current ,and under voltage of circuit and equipment. Alarm contacts size: 1N/O and 1N/C Wiring Diagram Of Auxiliary Contacts: State of MCCB State of alarm contacts diagram of wiring Close position Open position DAM1-125/160BC DAM1(ABB)-125,160A DAM1-250/400BCDAM1(ABB)-250A,400A DZ20-100BCDZ20-100A DZ20-225BC DZ20-225A ... -
-
China Cheap price Elctronic Rccb - DAL7-63 Residual Current Circuit Breaker(RCCB) – DaDa
Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)... -
-
Professional China Distribution Box Plastic - Modular Distribution Box (BE series) – DaDa
Technical Specification Product series: embedded mounting distribution box/surface mountingdistribution box Ways:4way, 7way, 10way, 12way, 14way, 16way, 18way, 20way, 24way(embedded mounting), 28way, 40way Products: 1.embedded mounting BEP-A 104, BEP-A 107, BEP-A 110, BEP-A 112. BEP-A 114, BEP-A 116, BEP-A 118, BEP-A 120, BEP-A124, BEP-A228, BEP-A240 2.surface mounting BEP-M 104, BEP-M 107, BEP-M 110, BEP-M 112, BEP-M 114, BEP-M116, BEP-M 118, BEP-M 120, BEP-M 228, BEP-M 24... -
New Arrival China Industrial circuit breaker – DAM1 Series Thermal And Magnetic Adjustable Type Moulded Case Circuit Breaker(MCCB) – DaDa
Advantages • Wide range:160A to 1600A(AC) • Compact dimensions • Adjustable thermal setting(70-100%)In. • Adjustable magnetic setting(5-10times)In. • Push to trip button provision. • Separate main and arcing contacts • Wide range of accessories. Characteristic Curve For Tame MCCB Electrical Parameters Of DAM1 MCCB Adjustable Type Molded Case Circuit Breaker Thermal and magnetic adjustable type MCCB Photo Model code Icu (KA) Ics (KA) Rated Current -In Ui(V) U... -
High Performance C10 Circuit Breaker - C45 4P Miniature Circuit Breaker – DaDa
Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1... -
Chinese wholesale Rcbo Protection - RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection – DaDa
Introduction Residual current operated circuit breakers with overcurrent protection ABDT-63 are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection. They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting. -
High Quality Ac Contactor - Contactor – DaDa
Introduction The structure of DA Type’s contactor is compact ;its volume is small;long perfomance life;Working stability and reliability ;installation is easy maintenance .Accessories of auxiliary contacts are plentiful it meet the various different market needs. It is mainly applied to control in motors ,electric line ,code wire ,bypass and lighting etc. of civilian and Industry. The main technical data: Main Circuit Rating Current: 9一370 A Motor power: 4一200KW (400V,AC-3)