Home
About Us
Factory Tour
Process Quality
Profile
Certification
History
Download
Video
FAQs
Product
Moulded Case Circuit Breaker丨MCCB
DAM1 丨MCCB
Fixed Type丨MCCB
Electronic Type 丨MCCB
Thermal And Magnetic Adjustable 丨MCCB
Thermal Adjustable Type 丨MCCB
DAM1 ISOMAX S Series丨MCCB
CM1 丨MCCB
CM1E Electronic 丨MCCB
DAM2 丨MCCB
DAM2 Electronic 丨MCCB
DAM3 丨MCCB
DAM4 丨MCCB DPX
DAM5 丨MCCB 3VL
DAM7 丨MCCB ABE
DAM8 丨MCCB ABN
DAM9 丨MCCB NF
DAM10 丨MCCB NS
Miniature Circuit Breaker丨MCB
NOVA 丨MCB
DAB5-63 丨MCB
DAB6-63 丨MCB
DAB7-63 丨MCB DC
DAB6-100 丨MCB
DAB6丨MCB
BA47-29 MCB
HVS 丨MCB
HVS丨MCB with window
HVS 丨 Isolator
C65丨MCB
DAB7-100 丨MCB
DAB7-125 丨MCB
DAB7-63 丨MCB
DAB7丨MCB L7
C45 丨MCB
MCB Accessory
DAB7N-40 DPN 丨MCB
RCBO
DABF-63 Electromagnetical 丨RCBO
DABL-63 Electronic 丨RCBO
DAB7NL-32 DPN 丨RCBO
ABDT-63 丨RCBO
ELCB丨RCCB
RTF1L-63 丨RCCB
DAB6LE-63 丨RCCB
DAF360 丨RCCB
DAL1-63 丨RCCB
DAL2-63 丨RCCB
DAL3-63 丨RCCB
DAL4-63 丨RCCB
DAL5-63 丨RCCB
DAL6-63 丨RCCB
DAL7-63 丨RCCB
DAL8-63 丨RCCB
DAL9-63 丨RCCB
Dal10-63 丨RCCB
ELCB丨CBR MCCB
DAM1L-125 丨CBR MCCB
DAM1L-160丨CBR MCCB
DAM1L-250丨CBR MCCB
DAM1L-630 丨CBR MCCB
CM1LE 丨CBR MCCB
Air Circuit Breaker丨ACB
Contactor
Motor Protection Circuit Breaker丨MPCB
Modular Distribution Box
MPH Shrinkable Busbar Conjunction Box
Circuit Breaker Accessory
News&Events
Exhibition
Product news
Our Advantage
Contact Us
English
product
Home
Featured
Well-designed Circuit Breaker Protection - DAB6 Series Miniature Circuit Breaker(MCB) – DaDa
Advantages • Two types of short circuit protection. • Wide range of operating temperatures from –40 to +50° С. • Updated wider engagement lever with improved contact area. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. MCB DAB6-63 For protection of general power distribution (IEC/EN 60898-1) Poles 1P 2P 3P 4P Electrical performance Functions short circuit protection,overload protection,isolationg,co...
inquiry
detail
Good Quality Earth Leakage Circuit Breaker - DAM1L-250 CBR ELCB Earth Leakage Protection Circuit Breaker – DaDa
This circuit breaker also has the following protection: • It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection. • Provide protection against the danger of increasing ground voltage due to insulation damage; • Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection. • Circuit breakers with rated current of 500A and below can also be used for infrequent start, br...
inquiry
detail
Manufacturing Companies for 15 Amp Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa
Technical parameter of DAB7-100 8kA miniature circuit breaker Standard of conformity: IEC60898, GB10963 Rated voltage: 230/400V, 50HZ Rated breaking capacity: 10KA (6-63A), 8KA (80-100A) Protection grade: IP20 Flame retardant grade: grade2 Endurance (power-driven): no less than 8,000 times of opening Endurance (manual operation): no less than 20,000times of opening Mechanical parameters of DAB7-100 8kA miniature circuit breaker Electric wire: 1~35mm2 Connection mode: There are two kinds of co...
inquiry
detail
2018 Good Quality Ac Motor Contactor - Contactor – DaDa
Introduction The structure of DA Type’s contactor is compact ;its volume is small;long perfomance life;Working stability and reliability ;installation is easy maintenance .Accessories of auxiliary contacts are plentiful it meet the various different market needs. It is mainly applied to control in motors ,electric line ,code wire ,bypass and lighting etc. of civilian and Industry. The main technical data: Main Circuit Rating Current: 9一370 A Motor power: 4一200KW (400V,AC-3)
inquiry
detail
High Quality micro circuit breaker - MCB Auxiliary Alarm Contact – DaDa
Use classes Ue(V) Ie(A) Number of contacts AC-12 230 2 2 groups of transfer contacts AC-15 230 1 DC-12 110 0.5 Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt t...
inquiry
detail
Wholesale Price China Rcbo 1 Pole – RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection – DaDa
Introduction Residual current operated circuit breakers with overcurrent protection ABDT-63 are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection. They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting.
inquiry
detail
Chinese wholesale Mcb Circuit Breaker - DAB7 Series Miniature Circuit Breaker(MCB) – DaDa
Advantages • Two types of overcurrent protection – thermal and electromagnetic. • High Breaker capacity 10KA • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Technical Features MCB DAB7-63 For protection of general power distribution (IEC/E...
inquiry
detail
Popular Design for 32a Circuit Breaker - DAB6 Series Miniature Circuit Breaker(MCB) – DaDa
Advantages • Two types of short circuit protection. • Wide range of operating temperatures from –40 to +50° С. • Updated wider engagement lever with improved contact area. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. MCB DAB6-63 For protection of general power distribution (IEC/EN 60898-1) Poles 1P 2P 3P 4P Electrical performance Functions short circuit protection,overload protection,isolationg,co...
inquiry
detail
2018 wholesale price thermal protection circuit breaker - DAM1 400 MCCB ABB ISOMAX – DaDa
Advantages •Easy independent installation of auxiliary devices: •Alarm contact; •Auxiliary contact; •Under voltage release; •Shunt release; •Handle operating mechanism; •Electrical operating mechanism; •Plug-in device; •Draw-out device;. •Standard set of each circuit breaker consists of connecting busbars or cable lugs, phase separators, a set of screws and nuts for its mounting ont•an installation panel. •With the help of special clamp 125 and 160 units can be installed ont•a DIN-rail. •Weig...
inquiry
detail
Manufacturer for Auxiliary Contact Switch - Electrical Operating Mechanism (Motor) – DaDa
DAM1(ABB) Electrical Operating Mechanism The electrical operating mechanism is available remote close of MCCB The types of electrical operating mechanism are shown in table 2 Types Of Electrical Operating Mechanism: Table 2 Rated current of frame size Inm Types of electrical Operating Mechanism CD1 CD2 CD3 CD 63A - CD2-63 - - 100A - CD2-100 - - 160A - CD2-160 - - 250A CD1-250 CD2-250 - CD-250 400A CD1-400 - - CD-400...
inquiry
detail
Good Quality Residual Current Circuit Breaker - DAF360 Series Residual Current Circuit Breakers – DaDa
Introduction If a ground fault current is detected by the DAF360 residual current circuit breaker, it will compare it to the ground leakage release current value and the circuit breaker will immediately break the circuit if the former is greater than the latter.Circuit breakers can connect ground systems in order to protect the charged body from indirect contact. It also functions to direct contact charged body additional protection if the rated residual current value is greater than ...
inquiry
detail
Good Quality Earth Leakage Circuit Breaker - DAM1L-125 CBR ELCB Earth Leakage Protection Circuit Breaker – DaDa
This circuit breaker also has the following protection: • It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection. • Provide protection against the danger of increasing ground voltage due to insulation damage; • Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection. • Circuit breakers with rated current of 500A and below can also be used for infrequent start, br...
inquiry
detail
<<
< Previous