product

  • 2018 wholesale price thermal protection circuit breaker - DAM1 400 MCCB ABB ISOMAX – DaDa

    2018 wholesale price thermal protection circuit breaker - DAM1 400 MCCB ABB ISOMAX – DaDa

    Advantages •Easy independent installation of auxiliary devices: •Alarm contact; •Auxiliary contact; •Under voltage release; •Shunt release; •Handle operating mechanism; •Electrical operating mechanism; •Plug-in device; •Draw-out device;. •Standard set of each circuit breaker consists of connecting busbars or cable lugs, phase separators, a set of screws and nuts for its mounting ont•an installation panel. •With the help of special clamp 125 and 160 units can be installed ont•a DIN-rail. •Weig...
  • 2018 Good Quality Alarm Contacts - Auxiliary Contacts – DaDa

    2018 Good Quality Alarm Contacts - Auxiliary Contacts – DaDa

    Application The auxiliary contacts is intended for automatical controlling of the auxiliary circuit of MCCB,such as indication of the open and close states of MCCB.  Auxiliary Contacts Size  1N/O and 1N/C  2N/O and2N/C  4N/O and 4N/C  Wiring Diagram Of Auxiliary Contacts State of MCCB State ofauxiliary contacts diagram of wiring Close position 1 set of auxiliary contacts,but2 sets of contacts to be supplied For Inm=63A-225A          2 set of auxiliary contacts,but4 sets...
  • China Factory for Home Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa

    China Factory for Home Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa

    Technical parameter of DAB7-100 8kA miniature circuit breaker Standard of conformity: IEC60898, GB10963 Rated voltage: 230/400V, 50HZ Rated breaking capacity: 10KA (6-63A), 8KA (80-100A) Protection grade: IP20 Flame retardant grade: grade2 Endurance (power-driven): no less than 8,000 times of opening Endurance (manual operation): no less than 20,000times of opening Mechanical parameters of DAB7-100 8kA miniature circuit breaker Electric wire: 1~35mm2 Connection mode: There are two kinds of co...
  • 18 Years Factory Short Circuit Breaker - MCB Under Voltage Release – DaDa

    18 Years Factory Short Circuit Breaker - MCB Under Voltage Release – DaDa

    Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. ...
  • Factory Price 3 Amp Circuit Breaker - HVS  MCB  circuit breaker – DaDa

    Factory Price 3 Amp Circuit Breaker - HVS MCB circuit breaker – DaDa

    Safety Terminals To avoid improper cable termination, the safety terminals guide the cable towards the cage terminal for systematic termination Bi Stable Clip Every device is provided with a dual position DIN rail clip, so it becomes much easier to change a device from a device bank connected to a bus-bar, without disturbing the existing wiring Large Cable Terminals Suitable for copper and aluminum cables, these terminals are compatible with cables upto 35 mm 2 cross section area ...
  • China Supplier Overload Circuit Breaker - DAB6 Series Miniature Circuit Breaker(MCB) – DaDa

    China Supplier Overload Circuit Breaker - DAB6 Series Miniature Circuit Breaker(MCB) – DaDa

    Advantages • Two types of short circuit protection. • Wide range of operating temperatures from –40 to +50° С. • Updated wider engagement lever with improved contact area. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. MCB DAB6-63 For protection of general power distribution (IEC/EN 60898-1) Poles 1P 2P 3P 4P Electrical performance Functions short circuit protection,overload protection,isolationg,co...
  • Manufacturer for Ac Dc Contactor - Contactor – DaDa

    Manufacturer for Ac Dc Contactor - Contactor – DaDa

    Introduction The structure of DA Type’s contactor is compact ;its volume is small;long perfomance life;Working stability and reliability ;installation is easy maintenance .Accessories of auxiliary contacts are plentiful it meet the various different market needs. It is mainly applied to control in motors ,electric line ,code wire ,bypass and lighting etc. of civilian and Industry. The main technical data: Main Circuit Rating Current: 9一370 A Motor power: 4一200KW (400V,AC-3)
  • Professional China Id Rccb - DAL8-63 Residual Current Circuit Breaker(RCCB) – DaDa

    Professional China Id Rccb - DAL8-63 Residual Current Circuit Breaker(RCCB) – DaDa

    Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(...
  • Manufacturing Companies for 15 Amp Circuit Breaker - DAB7N-40 Series DPN Miniature Circuit Breaker(MCB) – DaDa

    Manufacturing Companies for 15 Amp Circuit Breaker - DAB7N-40 Series DPN Miniature Circuit Breaker(MCB) – DaDa

     Advantages • Two types of overcurrent protection – thermal and electromagnetic. • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Electrical Parameters of DAB7N-40 Min iature Circuit Breaker Standard of conformity: IEC60898, GB10963 Rated power: ...
  • 2018 High quality Motor Rated Breaker - GV-M Motor Protection Circuit Breaker – DaDa

    2018 High quality Motor Rated Breaker - GV-M Motor Protection Circuit Breaker – DaDa

    Application GV series motor protection circuit breaker are mainly used fo the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A) ...
  • Professional China Id Rccb - DAL9-63 Residual Current Circuit Breaker(RCCB) – DaDa

    Professional China Id Rccb - DAL9-63 Residual Current Circuit Breaker(RCCB) – DaDa

    Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)...
  • High Performance C10 Circuit Breaker - C45 3P  Miniature Circuit Breaker – DaDa

    High Performance C10 Circuit Breaker - C45 3P Miniature Circuit Breaker – DaDa

    Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1P...