Home
About Us
Factory Tour
Process Quality
Profile
Certification
History
Download
Video
FAQs
Product
Moulded Case Circuit Breaker丨MCCB
DAM1 丨MCCB
Fixed Type丨MCCB
Electronic Type 丨MCCB
Thermal And Magnetic Adjustable 丨MCCB
Thermal Adjustable Type 丨MCCB
DAM1 ISOMAX S Series丨MCCB
CM1 丨MCCB
CM1E Electronic 丨MCCB
DAM2 丨MCCB
DAM2 Electronic 丨MCCB
DAM3 丨MCCB
DAM4 丨MCCB DPX
DAM5 丨MCCB 3VL
DAM7 丨MCCB ABE
DAM8 丨MCCB ABN
DAM9 丨MCCB NF
DAM10 丨MCCB NS
Miniature Circuit Breaker丨MCB
NOVA 丨MCB
DAB5-63 丨MCB
DAB6-63 丨MCB
DAB7-63 丨MCB DC
DAB6-100 丨MCB
DAB6丨MCB
BA47-29 MCB
HVS 丨MCB
HVS丨MCB with window
HVS 丨 Isolator
C65丨MCB
DAB7-100 丨MCB
DAB7-125 丨MCB
DAB7-63 丨MCB
DAB7丨MCB L7
C45 丨MCB
MCB Accessory
DAB7N-40 DPN 丨MCB
RCBO
DABF-63 Electromagnetical 丨RCBO
DABL-63 Electronic 丨RCBO
DAB7NL-32 DPN 丨RCBO
ABDT-63 丨RCBO
ELCB丨RCCB
RTF1L-63 丨RCCB
DAB6LE-63 丨RCCB
DAF360 丨RCCB
DAL1-63 丨RCCB
DAL2-63 丨RCCB
DAL3-63 丨RCCB
DAL4-63 丨RCCB
DAL5-63 丨RCCB
DAL6-63 丨RCCB
DAL7-63 丨RCCB
DAL8-63 丨RCCB
DAL9-63 丨RCCB
Dal10-63 丨RCCB
ELCB丨CBR MCCB
DAM1L-125 丨CBR MCCB
DAM1L-160丨CBR MCCB
DAM1L-250丨CBR MCCB
DAM1L-630 丨CBR MCCB
CM1LE 丨CBR MCCB
Air Circuit Breaker丨ACB
Contactor
Motor Protection Circuit Breaker丨MPCB
Modular Distribution Box
MPH Shrinkable Busbar Conjunction Box
Circuit Breaker Accessory
News&Events
Exhibition
Product news
Our Advantage
Contact Us
English
product
Home
Featured
Manufacturer for 45a Rcbo - DABL-63 RCBO 6KA Residual Current Operated Circuit Breaker – DaDa
Advantages • Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series. • The most subtle electric shock hazard protection in case of direct contact with conducting parts. • Independent contact position indicator. • Wide range of operating temperatures from –25 to +40° С. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. • “TEST”button for checking the ...
inquiry
detail
Good Quality Shunt Release - Shunt Release – DaDa
The shunt release is intended for remote controlling of opera of MCCB Release instantaneous duty. Characteristics of Shunt release: Electricalaccessories Shunt release Range ofsupply voltage (0.7-1.1)) x Us Rated controlsupply voltage us Power supply AC 50Hz 220V 380V Power loss 150V 150V DC 110V 220V Power loss 150V Wiring diagram of Shunt release: SB2- Opening Push-putton(ready by user ) P3,P4- Terminal number Us- Control power QF -Au...
inquiry
detail
Low price for 40 Amp Circuit Breaker - MCB Shunt Release – DaDa
Installation and Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. 2. The...
inquiry
detail
2018 High quality 25 Amp Rcbo - DABL-63 Nova Series Residual Current Operated Circuit Breakers With Overcurrent Protection – DaDa
Advantages • Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series. • The most subtle electric shock hazard protection in case of direct contact with conducting parts. • Independent contact position indicator. • Wide range of operating temperatures from –25 to +40° С. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. • “TEST” button for checking the device’s ope...
inquiry
detail
China wholesale thermal overload circuit breaker - DAM1 630 Series Moulded Case Circuit Breaker – DaDa
Thermal-Magnetic Circuit Breakers Thermal protection function:(For protection under over load conditions) Bimetal, which provides thermal protection, consists of combination of two metals with different extension coefficients under heat. When bimetal is heated, it bends towards the metal with less extension. In this way, a notch that assists opening of the breaker mechanism is released to disable the breaker. Bending speed of bimetal is in direct proportion with size of the current passing t...
inquiry
detail
China Cheap price 6 Amp Rcbo - RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection – DaDa
Introduction Residual current operated circuit breakers with overcurrent protection ABDT-63 are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection. They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting.
inquiry
detail
Manufacturer for 10a Mccb - DAM7 Series Moulded Case Circuit Breaker(MCCB) – DaDa
Type Number of poles Rated current in(A) Ultimate short circuit breaking capacity(KA),Icu DC AC50/60HZ 125V 250v 220/240V 380V 415V 440/460V 480/500v 600v ABE52b 2 10,15,20,30,40,50 5 2.5 10 7.5 5 5 2.5 2.5 ABE53b 3 10,15,20,30,40,50 5 2.5 10 7.5 5 5 2.5 2.5 ABE54b 4 10,15,20,30,40,50 5 2.5 10 7.5 5 5 2.5 2.5 ABE102b 2 10,15,20,30,40,50,60,75,100 10 5 25 14 10 10 7.5...
inquiry
detail
China Cheap price Thermal Adjustable circuit breaker - DAM5 Series Moulded Case Circuit Breaker(MCCB) – DaDa
Application DAM5 series MCCB is one of new products developed and manufactured by adopting international advanced technology. It is supplied with rated insutating voltage 690V and used for circuit of AC 50/60Hz, rated operating voltage AC 415V or below, rated opereating current from 16A to 630A. It is designed for protection of electric circuit, motors, transformers and other equipments. The products conforms to IEC60947-2 standard. Specification Type DAM5-160X DAM5-160 DAM5-250 D...
inquiry
detail
Professional China A Type Ac Type Rcbo - RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection – DaDa
Introduction Residual current operated circuit breakers with overcurrent protection ABDT-63 are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection. They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting.
inquiry
detail
Hot New Products 2 Pole Rccb – DAL9-63 Residual Current Circuit Breaker(RCCB) – DaDa
Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)...
inquiry
detail
2018 wholesale price thermal protection circuit breaker - DAM1 400 MCCB ABB ISOMAX – DaDa
Advantages •Easy independent installation of auxiliary devices: •Alarm contact; •Auxiliary contact; •Under voltage release; •Shunt release; •Handle operating mechanism; •Electrical operating mechanism; •Plug-in device; •Draw-out device;. •Standard set of each circuit breaker consists of connecting busbars or cable lugs, phase separators, a set of screws and nuts for its mounting ont•an installation panel. •With the help of special clamp 125 and 160 units can be installed ont•a DIN-rail. •Weig...
inquiry
detail
Hot-selling Thermal Circuit Breaker - DAB5 MCB – DaDa
Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa...
inquiry
detail
<<
< Previous
216
217
218
219
220
221
222
Next >
>>
Page 219 / 476