-
Wholesale Price China Rcbo 1 Pole – DAB7LN-40 series DPN Residual Current Operation Circuit Breaker(RCBO) – DaDa
Installation method: Using 35mm guide rail according to IEC standard Terminal type: Dual-purpose terminal can be connected to the bus bar and conductor. Terminal connection ability: conductor 1-25mm2, bus bar thickness 0.8-2mm Guide rail: DIN35guide rail Functions of DAB7LN-40 residual current circuit breaker Short circuit protection, overload protection and isolation. Electrical Parameters of DAB7LN-40 Residual Current Circuit Breaker Number of poles 1P+N(18mm) Rated frequency 50-60H... -
Fast delivery Marine Circuit Breaker - C45 2P Miniature Circuit Breaker – DaDa
Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1P 2P... -
OEM/ODM China Mccb 300 A - DAM7 Series Moulded Case Circuit Breaker(MCCB) – DaDa
Type Number of poles Rated current in(A) Ultimate short circuit breaking capacity(KA),Icu DC AC50/60HZ 125V 250v 220/240V 380V 415V 440/460V 480/500v 600v ABE52b 2 10,15,20,30,40,50 5 2.5 10 7.5 5 5 2.5 2.5 ABE53b 3 10,15,20,30,40,50 5 2.5 10 7.5 5 5 2.5 2.5 ABE54b 4 10,15,20,30,40,50 5 2.5 10 7.5 5 5 2.5 2.5 ABE102b 2 10,15,20,30,40,50,60,75,100 10 5 25 14 10 10 7.5... -
China Supplier Overload Circuit Breaker - MCB Shunt Release – DaDa
Installation and Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. 2. The... -
Trending Products Air Break Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa
Technical parameter of DAB7-100 8kA miniature circuit breaker Standard of conformity: IEC60898, GB10963 Rated voltage: 230/400V, 50HZ Rated breaking capacity: 10KA (6-63A), 8KA (80-100A) Protection grade: IP20 Flame retardant grade: grade2 Endurance (power-driven): no less than 8,000 times of opening Endurance (manual operation): no less than 20,000times of opening Mechanical parameters of DAB7-100 8kA miniature circuit breaker Electric wire: 1~35mm2 Connection mode: There are two kinds of co... -
2018 Good Quality Rcbo Electrical - RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection – DaDa
Introduction Residual current operated circuit breakers with overcurrent protection ABDT-63 are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection. They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting. -
China wholesale Motor Circuit Protector - GV-M Motor Protection Circuit Breaker – DaDa
Application GV series motor protection circuit breaker are mainly used fo the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A) ... -
2018 High quality Electromagnetic Rccb - DAL7-63 Residual Current Circuit Breaker(RCCB) – DaDa
Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)... -
Renewable Design for Time Delay Circuit Breaker - C65 MCB – DaDa
■ Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A ■ Rated working voltage: 110V, 230V ~ (1P, 1P + N), 400V ~ (2 ~ 4P, 3P + N) ■ Isolation □ Mechanical contact indication window, realistic cut-off instructions □ The window is green and the contact is in the open state. The window is red and the contact is in the closed state ■ Impulse withstand voltage: 4kV ■ Max withstand current: 6kA Circuit Breaker ■ Mechanical life: 20,000 times ■ Electrical life: 10000 times ■ Am... -
Professional China Distribution Box Plastic - Modular Plastic Empty Enclosure For MCB IP40 (TXM series) Plastic base – DaDa
Model Description TXM: series of distribution box Numbers of circuit:4,6,8,12,15,18,24,36 M:means Open mounted R:means Concealed mounted A:the cover is transparent P: plastic base Parameters ▪ Rated current: 63 [A] ▪ Short-circuit making current: 10 (KA) ▪ Shell protection grade: IP40; ▪ Shell material: ABS polymeric carbon ▪ Color: White ▪ Face covering: Transparent Outline Dimension Surface Flush TXM distribution box(plastic) Carton L*W*H(cm) (PCS/CTN) G.W.... -
Newly Arrival Residual Circuit Breaker - DAB6-100 Miniature Circuit Breaker – DaDa
Application DAB6-100 is such features as delicate appearance, light weight, excellent and reliableperformance, high breaking capacity, rapid tripping and mounted by rail. Its enclosure and com-ponents adopts high fire-retarding and shock-resistance plastic of long durability. It mainly servesfor protecting the circuits of AC 50Hz, 230V of single pole, 400V of two poles or three or fourpoles from overload or short-circuit, and also for unfrequent making and breaking electricalapparatus and lig... -
2018 High quality 4 Pole Earth Leakage Circuit Breaker – DAM1L Series Earth Leakage protection Circuit Breaker (ELCB) – DaDa
Under normal conditions,It can also be used for infrequent switching of lines. This circuit breaker also has the following protection: • It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection. • Provide protection against the danger of increasing ground voltage due to insulation damage; • Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection. • Circuit breaker...