  • Factory Price 3 Amp Circuit Breaker - HVS  MCB  circuit breaker – DaDa

    Factory Price 3 Amp Circuit Breaker - HVS MCB circuit breaker – DaDa

    Safety Terminals To avoid improper cable termination, the safety terminals guide the cable towards the cage terminal for systematic termination Bi Stable Clip Every device is provided with a dual position DIN rail clip, so it becomes much easier to change a device from a device bank connected to a bus-bar, without disturbing the existing wiring Large Cable Terminals Suitable for copper and aluminum cables, these terminals are compatible with cables upto 35 mm 2 cross section area ...
  • China Supplier Overload Circuit Breaker - DAB6 Series Miniature Circuit Breaker(MCB) – DaDa

    China Supplier Overload Circuit Breaker - DAB6 Series Miniature Circuit Breaker(MCB) – DaDa

    Advantages • Two types of short circuit protection. • Wide range of operating temperatures from –40 to +50° С. • Updated wider engagement lever with improved contact area. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. MCB DAB6-63 For protection of general power distribution (IEC/EN 60898-1) Poles 1P 2P 3P 4P Electrical performance Functions short circuit protection,overload protection,isolationg,co...
  • Manufacturer for Ac Dc Contactor - Contactor – DaDa

    Manufacturer for Ac Dc Contactor - Contactor – DaDa

    Introduction The structure of DA Type’s contactor is compact ;its volume is small;long perfomance life;Working stability and reliability ;installation is easy maintenance .Accessories of auxiliary contacts are plentiful it meet the various different market needs. It is mainly applied to control in motors ,electric line ,code wire ,bypass and lighting etc. of civilian and Industry. The main technical data: Main Circuit Rating Current: 9一370 A Motor power: 4一200KW (400V,AC-3)
  • Professional China Id Rccb - DAL8-63 Residual Current Circuit Breaker(RCCB) – DaDa

    Professional China Id Rccb - DAL8-63 Residual Current Circuit Breaker(RCCB) – DaDa

    Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(...
  • Manufacturing Companies for 15 Amp Circuit Breaker - DAB7N-40 Series DPN Miniature Circuit Breaker(MCB) – DaDa

    Manufacturing Companies for 15 Amp Circuit Breaker - DAB7N-40 Series DPN Miniature Circuit Breaker(MCB) – DaDa

     Advantages • Two types of overcurrent protection – thermal and electromagnetic. • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Electrical Parameters of DAB7N-40 Min iature Circuit Breaker Standard of conformity: IEC60898, GB10963 Rated power: ...
  • 2018 High quality Motor Rated Breaker - GV-M Motor Protection Circuit Breaker – DaDa

    2018 High quality Motor Rated Breaker - GV-M Motor Protection Circuit Breaker – DaDa

    Application GV series motor protection circuit breaker are mainly used fo the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A) ...
  • Professional China Id Rccb - DAL9-63 Residual Current Circuit Breaker(RCCB) – DaDa

    Professional China Id Rccb - DAL9-63 Residual Current Circuit Breaker(RCCB) – DaDa

    Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)...
  • High Performance C10 Circuit Breaker - C45 3P  Miniature Circuit Breaker – DaDa

    High Performance C10 Circuit Breaker - C45 3P Miniature Circuit Breaker – DaDa

    Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1P...
  • China OEM Three Phase Circuit Breaker - DAB7 L7 Mini circuit breaker – DaDa

    China OEM Three Phase Circuit Breaker - DAB7 L7 Mini circuit breaker – DaDa

      Product Model Pole Trip type Rated current DAB7-63 1P C 63 1P 2P 3P 4P B:Type B C:Type C D:Type D 1:1A 10:10A 32:32A 2:2A 16:16A 40:40A 3:3A 20:20A 50:50A 4:4A 25:25A 63:63A 6:6A   Normal operating conditions and installation conditions   ■ Ambient air temperature of L7 6/10KA Miniature Circuit Breaker: -5℃~40℃, and average temperature in 24h below +35℃. ■ Altitude of the installation site should not exceed 2000m. ■ Atmospheric relative humidity at ...
  • Professional China Motor Start Circuit Breaker - GV2 Mpcb Motor Protection Circuit Breaker  – DaDa

    Professional China Motor Start Circuit Breaker - GV2 Mpcb Motor Protection Circuit Breaker – DaDa

    Application GV-Me series motor protection circuit breaker are mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A)...
  • Massive Selection for Moulded Circuit Breaker - C45 4P  Miniature Circuit Breaker – DaDa

    Massive Selection for Moulded Circuit Breaker - C45 4P Miniature Circuit Breaker – DaDa

     Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1...
  • Chinese Professional Mccb 1000 Amp - DAM1 Series Thermal And Magnetic Adjustable Type Moulded Case Circuit Breaker(MCCB) – DaDa

    Chinese Professional Mccb 1000 Amp - DAM1 Series Thermal And Magnetic Adjustable Type Moulded Case Circuit Breaker(MCCB) – DaDa

    Advantages • Wide range:160A to 1600A(AC) • Compact dimensions • Adjustable thermal setting(70-100%)In. • Adjustable magnetic setting(5-10times)In. • Push to trip button provision. • Separate main and arcing contacts • Wide range of accessories. Characteristic Curve For Tame MCCB Electrical Parameters Of DAM1 MCCB Adjustable Type Molded Case Circuit Breaker Thermal and magnetic adjustable type MCCB Photo Model code  Icu (KA) Ics (KA) Rated Current -In   Ui(V) U...