    Technical parameter of DAB7-100 8kA miniature circuit breaker Standard of conformity: IEC60898, GB10963 Rated voltage: 230/400V, 50HZ Rated breaking capacity: 10KA (6-63A), 8KA (80-100A) Protection grade: IP20 Flame retardant grade: grade2 Endurance (power-driven): no less than 8,000 times of opening Endurance (manual operation): no less than 20,000times of opening Mechanical parameters of DAB7-100 8kA miniature circuit breaker Electric wire: 1~35mm2 Connection mode: There are two kinds of co...
  • High Quality Elcb Mccb - DAM1L-250 CBR ELCB Earth Leakage Protection Circuit Breaker – DaDa

    High Quality Elcb Mccb - DAM1L-250 CBR ELCB Earth Leakage Protection Circuit Breaker – DaDa

    This circuit breaker also has the following protection: • It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection. • Provide protection against the danger of increasing ground voltage due to insulation damage; • Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection. • Circuit breakers with rated current of 500A and below can also be used for infrequent start, br...
  • Good Quality Motor Protection Circuit Breaker - GV2 Mpcb Motor Protection Circuit Breaker  – DaDa

    Good Quality Motor Protection Circuit Breaker - GV2 Mpcb Motor Protection Circuit Breaker – DaDa

    Application GV-Me series motor protection circuit breaker are mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A)...
  • Factory wholesale 150 Amp Circuit Breaker - DAB7-63 Nova Series Miniature Circuit Breaker(MCB) – DaDa

    Factory wholesale 150 Amp Circuit Breaker - DAB7-63 Nova Series Miniature Circuit Breaker(MCB) – DaDa

    Advantages • Two types of overcurrent protection – thermal and electromagnetic. • High Breaker capacity 6/10KA • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Technical Features MCB DAB7-63 For protection of general power distribution (IEC/...
  • factory Outlets for 100a Circuit Breaker - DAB6 Series Miniature Circuit Breaker(MCB) – DaDa

    factory Outlets for 100a Circuit Breaker - DAB6 Series Miniature Circuit Breaker(MCB) – DaDa

    Advantages • Two types of short circuit protection. • Wide range of operating temperatures from –40 to +50° С. • Updated wider engagement lever with improved contact area. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. MCB DAB6-63 For protection of general power distribution (IEC/EN 60898-1) Poles 1P 2P 3P 4P Electrical performance Functions short circuit protection,overload protection,isolationg,co...
  • Bottom price 60 Amp Circuit Breaker - HVS  Isolator – DaDa

    Bottom price 60 Amp Circuit Breaker - HVS Isolator – DaDa

    Low Watt Loss Low power loss. Longer Electrical Life DesIgned for better and longer electrical life. Value for Money Assured reliability and service makes it value for money. Low power consumption, thus cost effective & energy saving Consumes less power, thus cost effective and energy saving.
  • High Quality for 1 Pole Circuit Breaker - DAB6 Series Miniature Circuit Breaker(MCB) – DaDa

    High Quality for 1 Pole Circuit Breaker - DAB6 Series Miniature Circuit Breaker(MCB) – DaDa

    Advantages • Two types of short circuit protection. • Wide range of operating temperatures from –40 to +50° С. • Updated wider engagement lever with improved contact area. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. MCB DAB6-63 For protection of general power distribution (IEC/EN 60898-1) Poles 1P 2P 3P 4P Electrical performance Functions short circuit protection,overload protection,isolationg,co...
  • Competitive Price for 400 Amp Circuit Breaker - C45 2P Miniature Circuit Breaker – DaDa

    Competitive Price for 400 Amp Circuit Breaker - C45 2P Miniature Circuit Breaker – DaDa

    Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1P 2P...
  • Hot sale Two Pole Circuit Breaker - C45 4P  Miniature Circuit Breaker – DaDa

    Hot sale Two Pole Circuit Breaker - C45 4P Miniature Circuit Breaker – DaDa

     Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1...
  • 2018 wholesale price Home circuit breaker - DAB7 L7 Mini circuit breaker – DaDa

    2018 wholesale price Home circuit breaker - DAB7 L7 Mini circuit breaker – DaDa

      Product Model Pole Trip type Rated current DAB7-63 1P C 63 1P 2P 3P 4P B:Type B C:Type C D:Type D 1:1A 10:10A 32:32A 2:2A 16:16A 40:40A 3:3A 20:20A 50:50A 4:4A 25:25A 63:63A 6:6A   Normal operating conditions and installation conditions   ■ Ambient air temperature of L7 6/10KA Miniature Circuit Breaker: -5℃~40℃, and average temperature in 24h below +35℃. ■ Altitude of the installation site should not exceed 2000m. ■ Atmospheric relative humidity at ...
  • Factory Price For Motor Circuit Breaker - MCB Auxiliary Alarm Contact – DaDa

    Factory Price For Motor Circuit Breaker - MCB Auxiliary Alarm Contact – DaDa

    Use classes Ue(V) Ie(A) Number of contacts AC-12 230 2 2 groups of transfer contacts AC-15 230 1 DC-12 110 0.5 Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt t...
  • 2018 High quality thermal magnetic circuit breaker - DAM3-630 MCCB Molded Case Circuit Breaker – DaDa

    2018 High quality thermal magnetic circuit breaker - DAM3-630 MCCB Molded Case Circuit Breaker – DaDa

    Overview The rated current of DAM3-630 molded case circuit breaker can reach up to 630A. These electrical devices are suitable for the protection of power distribution circuits with an alternating current of 50-60Hz and a rated operating current up to 1000A. They can also be used in electric motors for infrequent starting and overload protection as well as protection against short circuiting and undervoltage conditions. The circuit breakers feature the characteristics of small volume, high br...