product

  • 2018 High quality 25 Amp Rcbo - DABL-63 Nova Series Residual Current Operated Circuit Breakers With Overcurrent Protection – DaDa

    2018 High quality 25 Amp Rcbo - DABL-63 Nova Series Residual Current Operated Circuit Breakers With Overcurrent Protection – DaDa

    Advantages • Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series. • The most subtle electric shock hazard protection in case of direct contact with conducting parts. • Independent contact position indicator. • Wide range of operating temperatures from –25 to +40° С. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. • “TEST” button for checking the device’s ope...
  • Lowest Price for Double Circuit Breaker - DAB6-100 Miniature Circuit Breaker – DaDa

    Lowest Price for Double Circuit Breaker - DAB6-100 Miniature Circuit Breaker – DaDa

    Application DAB6-100 is such features as delicate appearance, light weight, excellent and reliableperformance, high breaking capacity, rapid tripping and mounted by rail. Its enclosure and com-ponents adopts high fire-retarding and shock-resistance plastic of long durability. It mainly servesfor protecting the circuits of AC 50Hz, 230V of single pole, 400V of two poles or three or fourpoles from overload or short-circuit, and also for unfrequent making and breaking electricalapparatus and lig...
  • 2018 China New Design MCB switch - DAB5 MCB – DaDa

    2018 China New Design MCB switch - DAB5 MCB – DaDa

    Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa...
  • Hot New Products Contactor 220 Volt – Contactor – DaDa

    Hot New Products Contactor 220 Volt – Contactor – DaDa

    Introduction The structure of DA Type’s contactor is compact ;its volume is small;long perfomance life;Working stability and reliability ;installation is easy maintenance .Accessories of auxiliary contacts are plentiful it meet the various different market needs. It is mainly applied to control in motors ,electric line ,code wire ,bypass and lighting etc. of civilian and Industry. The main technical data: Main Circuit Rating Current: 9一370 A Motor power: 4一200KW (400V,AC-3)
  • Manufacturer for Residual Circuit Current Breaker - DAL1-63 Residual Current Circuit Breakers – DaDa

    Manufacturer for Residual Circuit Current Breaker - DAL1-63 Residual Current Circuit Breakers – DaDa

    Introduction DAL1-63 residual current circuit breakers are protection equipment which must be used to protect human life against dangerous electric shocks or prevent the fires arising out of isolation mistakes thereby detecting isolation mistakes to occur within the plant in advance. Sigma residual current circuit breakers are produced with 2 and 4 poles in accordance with IEC EN 61008-1 standard and in compliance with CE norms under ISO 9001:2008 quality assurance system. What is the differe...
  • Hot sale Two Pole Circuit Breaker - DAB6-63 with transparent cover series miniature circuit breaker – DaDa
  • Good quality 300 Amp Circuit Breaker - DAB7-63 DC miniature Circuit Breaker – DaDa
  • PriceList for Double Pole Circuit Breaker - DAB7N-40 Series DPN Miniature Circuit Breaker(MCB) – DaDa

    PriceList for Double Pole Circuit Breaker - DAB7N-40 Series DPN Miniature Circuit Breaker(MCB) – DaDa

     Advantages • Two types of overcurrent protection – thermal and electromagnetic. • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Electrical Parameters of DAB7N-40 Min iature Circuit Breaker Standard of conformity: IEC60898, GB10963 Rated power: ...
  • Chinese wholesale Rcbo Protection - DABL-63 RCBO 6KA Residual Current Operated Circuit Breaker – DaDa

    Chinese wholesale Rcbo Protection - DABL-63 RCBO 6KA Residual Current Operated Circuit Breaker – DaDa

     Advantages • Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series. • The most subtle electric shock hazard protection in case of direct contact with conducting parts. • Independent contact position indicator. • Wide range of operating temperatures from –25 to +40° С. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. • “TEST”button for checking the ...
  • Good Quality Contactor - Contactor – DaDa

    Good Quality Contactor - Contactor – DaDa

    Introduction The structure of DA Type’s contactor is compact ;its volume is small;long perfomance life;Working stability and reliability ;installation is easy maintenance .Accessories of auxiliary contacts are plentiful it meet the various different market needs. It is mainly applied to control in motors ,electric line ,code wire ,bypass and lighting etc. of civilian and Industry. The main technical data: Main Circuit Rating Current: 9一370 A Motor power: 4一200KW (400V,AC-3)
  • Manufacturer for Auxiliary Contact Switch - Rotary Handle Mechanism – DaDa

    Manufacturer for Auxiliary Contact Switch - Rotary Handle Mechanism – DaDa

    Handle Operating Mechanism Series Rotary handle operating mechanism The rotary handle operating mechanism suitable for: 1. Closing and Opening of MCCB by the rotary handle on MCCB 2. Closing and Opening of MCCB by the rotary handle on the compartment door of switch board: 3. Interlocking  between handle the rotary operating mechanism and  compartment door to prevent the compartment door from being opened in case of MCCB in closed state. Customer can fit padlock on it for MCCB in open position...
  • China wholesale Motor Circuit Protector - GV-M Motor Protection Circuit Breaker – DaDa

    China wholesale Motor Circuit Protector - GV-M Motor Protection Circuit Breaker – DaDa

    Application GV series motor protection circuit breaker are mainly used fo the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A) ...