product

  • Professional China Plug-In Device And Draw-Out Device - Electrical Operating Mechanism (Motor) – DaDa

    Professional China Plug-In Device And Draw-Out Device - Electrical Operating Mechanism (Motor) – DaDa

    DAM1(ABB) Electrical Operating Mechanism The electrical operating mechanism is available remote close of MCCB The types of electrical operating mechanism are shown in table 2 Types Of Electrical Operating Mechanism:   Table 2 Rated current of frame size Inm Types of electrical Operating Mechanism CD1 CD2 CD3 CD 63A - CD2-63 - - 100A - CD2-100 - - 160A - CD2-160 - - 250A CD1-250 CD2-250 - CD-250 400A CD1-400 - - CD-400...
  • High Quality micro circuit breaker - MCB Auxiliary Alarm Contact – DaDa

    High Quality micro circuit breaker - MCB Auxiliary Alarm Contact – DaDa

    Use classes Ue(V) Ie(A) Number of contacts AC-12 230 2 2 groups of transfer contacts AC-15 230 1 DC-12 110 0.5 Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt t...
  • China Cheap price Mccb With Elcb - DAM1 -160L  ELCB Earth Leakage protection circuit breaker1 – DaDa

    China Cheap price Mccb With Elcb - DAM1 -160L ELCB Earth Leakage protection circuit breaker1 – DaDa

    This circuit breaker also has the following protection: • It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection. • Provide protection against the danger of increasing ground voltage due to insulation damage; • Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection. • Circuit breakers with rated current of 500A and below can also be used for infrequent start, br...
  • 2018 wholesale price Under Voltage Release - Auxiliary Contacts – DaDa

    2018 wholesale price Under Voltage Release - Auxiliary Contacts – DaDa

    Application The auxiliary contacts is intended for automatical controlling of the auxiliary circuit of MCCB,such as indication of the open and close states of MCCB.  Auxiliary Contacts Size  1N/O and 1N/C  2N/O and2N/C  4N/O and 4N/C  Wiring Diagram Of Auxiliary Contacts State of MCCB State ofauxiliary contacts diagram of wiring Close position 1 set of auxiliary contacts,but2 sets of contacts to be supplied For Inm=63A-225A          2 set of auxiliary contacts,but4 sets...
  • 2018 wholesale price Motor Protection Circuit – GV-M Motor Protection Circuit Breaker – DaDa

    2018 wholesale price Motor Protection Circuit – GV-M Motor Protection Circuit Breaker – DaDa

    Application GV series motor protection circuit breaker are mainly used fo the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A) ...
  • Good User Reputation for 125 Amp Circuit Breaker - C45 4P  Miniature Circuit Breaker – DaDa

    Good User Reputation for 125 Amp Circuit Breaker - C45 4P Miniature Circuit Breaker – DaDa

     Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1...
  • Good Quality Residual Current Circuit Breaker With Overcurrent Protection - DABL-63 RCBO 6KA Residual Current Operated Circuit Breaker – DaDa

    Good Quality Residual Current Circuit Breaker With Overcurrent Protection - DABL-63 RCBO 6KA Residual Current Operated Circuit Breaker – DaDa

     Advantages • Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series. • The most subtle electric shock hazard protection in case of direct contact with conducting parts. • Independent contact position indicator. • Wide range of operating temperatures from –25 to +40° С. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. • “TEST”button for checking the ...
  • New Arrival China Industrial circuit breaker – DAM1 630 Series MCCB ABB ISOMAX – DaDa

    New Arrival China Industrial circuit breaker – DAM1 630 Series MCCB ABB ISOMAX – DaDa

    Advantages •Easy independent installation of auxiliary devices: Alarm contact; Auxiliary contact; Under voltage release; Shunt release; Handle operating mechanism; Electrical operating mechanism; Plug-in device; Draw-out device;. •Standard set of each circuit breaker consists of connecting busbars or cable lugs, phase separators, a set of screws and nuts for its mounting ontan installation panel. •With the help of special clamp 125 and 160 units can be installed onta DIN-rail. •Weight and dim...
  • 2018 High quality Small circuit breaker - DAB7N-40 Series DPN Miniature Circuit Breaker(MCB) – DaDa

    2018 High quality Small circuit breaker - DAB7N-40 Series DPN Miniature Circuit Breaker(MCB) – DaDa

     Advantages • Two types of overcurrent protection – thermal and electromagnetic. • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Electrical Parameters of DAB7N-40 Min iature Circuit Breaker Standard of conformity: IEC60898, GB10963 Rated power: ...
  • Good Quality Thermal Shrink Busbar Box - MPH Series Busbar Conjunction Box (Heat Shrink Junction Box) 1kv10kv35kv – DaDa

    Good Quality Thermal Shrink Busbar Box - MPH Series Busbar Conjunction Box (Heat Shrink Junction Box) 1kv10kv35kv – DaDa

    Application Main busbar connector box in the electrical equipment at the electrical connection of the insulation protection, and high and low voltage switchgear circuit breakers are not deformed, heat is not deformed, heat does not shrink, the appearance of the corners, wall thickness Uniform, accurate size, stable performance, smooth and meticulous appearance, long service life, etc., can better highlight the equipment grade, the overall effect is more obvious for our company’s product...
  • Manufacturer for 45a Rcbo - DAB7LN-40 series DPN Residual Current Operation Circuit Breaker(RCBO) – DaDa

    Manufacturer for 45a Rcbo - DAB7LN-40 series DPN Residual Current Operation Circuit Breaker(RCBO) – DaDa

    Installation method: Using 35mm guide rail according to IEC standard Terminal type: Dual-purpose terminal can be connected to the bus bar and conductor. Terminal connection ability: conductor 1-25mm2, bus bar thickness 0.8-2mm Guide rail: DIN35guide rail Functions of DAB7LN-40 residual current circuit breaker Short circuit protection, overload protection and isolation. Electrical Parameters of DAB7LN-40 Residual Current Circuit Breaker Number of poles 1P+N(18mm) Rated frequency 50-60H...
  • Chinese Professional Mccb 1000 Amp - DAM8 Series Moulded Case Circuit Breaker(MCCB) – DaDa

    Chinese Professional Mccb 1000 Amp - DAM8 Series Moulded Case Circuit Breaker(MCCB) – DaDa

    AF 50AF 100AF 250AF Type N-type N-type N-type Type and Pole 3-Pole ABN53C ABN103C ABN203C Rated current,In A 15.20.30.40.50 15.20.30.40.50.60.75.100 100.125.150.175.200.225.250 Rated operational voltage,Ue AC(V) 690 690 690 DC(V) 500 500 500 Rated insulation voltage,Ui V 750 750 750 Rated impulse withstand voltage,Uimp kV 8 8 8 Rated short-circuit breaking capacity(Icu) kA (Sym),KSC8321,IEC 60947-2     AC 690V ...