Home
About Us
Factory Tour
Process Quality
Profile
Certification
History
Download
Video
FAQs
Product
Moulded Case Circuit Breaker丨MCCB
DAM1 丨MCCB
Fixed Type丨MCCB
Electronic Type 丨MCCB
Thermal And Magnetic Adjustable 丨MCCB
Thermal Adjustable Type 丨MCCB
DAM1 ISOMAX S Series丨MCCB
CM1 丨MCCB
CM1E Electronic 丨MCCB
DAM2 丨MCCB
DAM2 Electronic 丨MCCB
DAM3 丨MCCB
DAM4 丨MCCB DPX
DAM5 丨MCCB 3VL
DAM7 丨MCCB ABE
DAM8 丨MCCB ABN
DAM9 丨MCCB NF
DAM10 丨MCCB NS
Miniature Circuit Breaker丨MCB
NOVA 丨MCB
DAB5-63 丨MCB
DAB6-63 丨MCB
DAB7-63 丨MCB DC
DAB6-100 丨MCB
DAB6丨MCB
BA47-29 MCB
HVS 丨MCB
HVS丨MCB with window
HVS 丨 Isolator
C65丨MCB
DAB7-100 丨MCB
DAB7-125 丨MCB
DAB7-63 丨MCB
DAB7丨MCB L7
C45 丨MCB
MCB Accessory
DAB7N-40 DPN 丨MCB
RCBO
DABF-63 Electromagnetical 丨RCBO
DABL-63 Electronic 丨RCBO
DAB7NL-32 DPN 丨RCBO
ABDT-63 丨RCBO
ELCB丨RCCB
RTF1L-63 丨RCCB
DAB6LE-63 丨RCCB
DAF360 丨RCCB
DAL1-63 丨RCCB
DAL2-63 丨RCCB
DAL3-63 丨RCCB
DAL4-63 丨RCCB
DAL5-63 丨RCCB
DAL6-63 丨RCCB
DAL7-63 丨RCCB
DAL8-63 丨RCCB
DAL9-63 丨RCCB
Dal10-63 丨RCCB
ELCB丨CBR MCCB
DAM1L-125 丨CBR MCCB
DAM1L-160丨CBR MCCB
DAM1L-250丨CBR MCCB
DAM1L-630 丨CBR MCCB
CM1LE 丨CBR MCCB
Air Circuit Breaker丨ACB
Contactor
Motor Protection Circuit Breaker丨MPCB
Modular Distribution Box
MPH Shrinkable Busbar Conjunction Box
Circuit Breaker Accessory
News&Events
Exhibition
Product news
Our Advantage
Contact Us
English
product
Home
Featured
Factory Cheap Hot Rcbo 2p - RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection – DaDa
Introduction Residual current operated circuit breakers with overcurrent protection ABDT-63 are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection. They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting.
inquiry
detail
China Cheap price Elctronic Rccb - DAL4-63 Residual Current Circuit Breaker(RCCB) – DaDa
Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)...
inquiry
detail
Professional China Id Rccb - DAL3-63 Residual Current Circuit Breaker(RCCB) – DaDa
Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)...
inquiry
detail
Trending Products Air Break Circuit Breaker - MCB Under Voltage Release – DaDa
Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. ...
inquiry
detail
New Delivery for 60a Circuit Breaker - DAB6-100 Miniature Circuit Breaker – DaDa
Application DAB6-100 is such features as delicate appearance, light weight, excellent and reliableperformance, high breaking capacity, rapid tripping and mounted by rail. Its enclosure and com-ponents adopts high fire-retarding and shock-resistance plastic of long durability. It mainly servesfor protecting the circuits of AC 50Hz, 230V of single pole, 400V of two poles or three or fourpoles from overload or short-circuit, and also for unfrequent making and breaking electricalapparatus and lig...
inquiry
detail
China wholesale Distribution Box Iron Base - SHPN Series Waterproof Distribution Box – DaDa
Outline Dimension Packing Information SHPN waterproof distribution box Carton L*W*H(cm) (PCS/CTN) G.W.(kgs/ctn) N.W.(kgs/ctn) SH4PN 4 way 510*355*450 30 10 9 SH6PN 6 way 540*355*430 20 16 15 SH9PN 9 way 540*425*465 20 19 18 SH12PN 12 way 595*485*575 20 27 26 SH18PN 18 way 595*485*405 10 19 18 SH24PN 24 way
inquiry
detail
China wholesale Electronic Rcbo - DABL-63 RCBO 6KA Residual Current Operated Circuit Breaker – DaDa
Advantages • Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series. • The most subtle electric shock hazard protection in case of direct contact with conducting parts. • Independent contact position indicator. • Wide range of operating temperatures from –25 to +40° С. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. • “TEST”button for checking the ...
inquiry
detail
Good Quality Contactor - Contactor – DaDa
Introduction The structure of DA Type’s contactor is compact ;its volume is small;long perfomance life;Working stability and reliability ;installation is easy maintenance .Accessories of auxiliary contacts are plentiful it meet the various different market needs. It is mainly applied to control in motors ,electric line ,code wire ,bypass and lighting etc. of civilian and Industry. The main technical data: Main Circuit Rating Current: 9一370 A Motor power: 4一200KW (400V,AC-3)
inquiry
detail
Manufacturer for Auxiliary Contact Switch - Under Voltage Release – DaDa
Application The under voltage is intended for under voltage protection of circuit and electric equipment. Release uniterrupted duty. Characteristics of under voltage release: Ue(V)Rated operation voltage AC380 AC220 DC110 DC220 Operation voltage (0.35-0.7)) x Ue Ensured closing voltage (0.85-1.1)) x Ue Ensured non closing voltage ≤0.35 Ue Power loss 10VA 4W Wiring Diagram Of Under Voltagerelease Us- Control power P1,P2- Terminal number ...
inquiry
detail
China Cheap price Motor Protection Breaker - GV2 Mpcb Motor Protection Circuit Breaker – DaDa
Application GV-Me series motor protection circuit breaker are mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A)...
inquiry
detail
Factory wholesale 15a Circuit Breaker - C45 4P Miniature Circuit Breaker – DaDa
Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1...
inquiry
detail
Quality Inspection for Motorized Circuit Breaker – DAB5 MCB – DaDa
Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa...
inquiry
detail
<<
< Previous
189
190
191
192
193
194
195
Next >
>>
Page 192 / 463
Hit enter to search or ESC to close