Home
About Us
Factory Tour
Process Quality
Profile
Certification
History
Download
Video
FAQs
Product
Moulded Case Circuit Breaker丨MCCB
DAM1 丨MCCB
Fixed Type丨MCCB
Electronic Type 丨MCCB
Thermal And Magnetic Adjustable 丨MCCB
Thermal Adjustable Type 丨MCCB
DAM1 ISOMAX S Series丨MCCB
CM1 丨MCCB
CM1E Electronic 丨MCCB
DAM2 丨MCCB
DAM2 Electronic 丨MCCB
DAM3 丨MCCB
DAM4 丨MCCB DPX
DAM5 丨MCCB 3VL
DAM7 丨MCCB ABE
DAM8 丨MCCB ABN
DAM9 丨MCCB NF
DAM10 丨MCCB NS
Miniature Circuit Breaker丨MCB
NOVA 丨MCB
DAB5-63 丨MCB
DAB6-63 丨MCB
DAB7-63 丨MCB DC
DAB6-100 丨MCB
DAB6丨MCB
BA47-29 MCB
HVS 丨MCB
HVS丨MCB with window
HVS 丨 Isolator
C65丨MCB
DAB7-100 丨MCB
DAB7-125 丨MCB
DAB7-63 丨MCB
DAB7丨MCB L7
C45 丨MCB
MCB Accessory
DAB7N-40 DPN 丨MCB
RCBO
DABF-63 Electromagnetical 丨RCBO
DABL-63 Electronic 丨RCBO
DAB7NL-32 DPN 丨RCBO
ABDT-63 丨RCBO
ELCB丨RCCB
RTF1L-63 丨RCCB
DAB6LE-63 丨RCCB
DAF360 丨RCCB
DAL1-63 丨RCCB
DAL2-63 丨RCCB
DAL3-63 丨RCCB
DAL4-63 丨RCCB
DAL5-63 丨RCCB
DAL6-63 丨RCCB
DAL7-63 丨RCCB
DAL8-63 丨RCCB
DAL9-63 丨RCCB
Dal10-63 丨RCCB
ELCB丨CBR MCCB
DAM1L-125 丨CBR MCCB
DAM1L-160丨CBR MCCB
DAM1L-250丨CBR MCCB
DAM1L-630 丨CBR MCCB
CM1LE 丨CBR MCCB
Air Circuit Breaker丨ACB
Contactor
Motor Protection Circuit Breaker丨MPCB
Modular Distribution Box
MPH Shrinkable Busbar Conjunction Box
Circuit Breaker Accessory
News&Events
Exhibition
Product news
Our Advantage
Contact Us
English
product
Home
Featured
Good Quality Shunt Release - Shunt Release – DaDa
The shunt release is intended for remote controlling of opera of MCCB Release instantaneous duty. Characteristics of Shunt release: Electricalaccessories Shunt release Range ofsupply voltage (0.7-1.1)) x Us Rated controlsupply voltage us Power supply AC 50Hz 220V 380V Power loss 150V 150V DC 110V 220V Power loss 150V Wiring diagram of Shunt release: SB2- Opening Push-putton(ready by user ) P3,P4- Terminal number Us- Control power QF -Au...
inquiry
detail
Chinese Professional Type A Rcbo - RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection – DaDa
Introduction Residual current operated circuit breakers with overcurrent protection ABDT-63 are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection. They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting.
inquiry
detail
Wholesale Price China Rcbo 1 Pole – DAB7LN-40 series DPN Residual Current Operation Circuit Breaker(RCBO) – DaDa
Installation method: Using 35mm guide rail according to IEC standard Terminal type: Dual-purpose terminal can be connected to the bus bar and conductor. Terminal connection ability: conductor 1-25mm2, bus bar thickness 0.8-2mm Guide rail: DIN35guide rail Functions of DAB7LN-40 residual current circuit breaker Short circuit protection, overload protection and isolation. Electrical Parameters of DAB7LN-40 Residual Current Circuit Breaker Number of poles 1P+N(18mm) Rated frequency 50-60H...
inquiry
detail
2018 China New Design Main Mccb - DAM1 800 MCCB Moulded Case Circuit Breaker – DaDa
Thermal-Magnetic Circuit Breakers Thermal protection function:(For protection under over load conditions) Bimetal, which provides thermal protection, consists of combination of two metals with different extension coefficients under heat. When bimetal is heated, it bends towards the metal with less extension. In this way, a notch that assists opening of the breaker mechanism is released to disable the breaker. Bending speed of bimetal is in direct proportion with size of the current passing...
inquiry
detail
2018 Good Quality Alarm Contacts - Under Voltage Release – DaDa
Application The under voltage is intended for under voltage protection of circuit and electric equipment. Release uniterrupted duty. Characteristics of under voltage release: Ue(V)Rated operation voltage AC380 AC220 DC110 DC220 Operation voltage (0.35-0.7)) x Ue Ensured closing voltage (0.85-1.1)) x Ue Ensured non closing voltage ≤0.35 Ue Power loss 10VA 4W Wiring Diagram Of Under Voltagerelease Us- Control power P1,P2- Terminal number ...
inquiry
detail
China Cheap price Shrink Joint Box - MPH Series Busbar Conjunction Box (Heat Shrink Junction Box) 1kv10kv35kv – DaDa
Application Main busbar connector box in the electrical equipment at the electrical connection of the insulation protection, and high and low voltage switchgear circuit breakers are not deformed, heat is not deformed, heat does not shrink, the appearance of the corners, wall thickness Uniform, accurate size, stable performance, smooth and meticulous appearance, long service life, etc., can better highlight the equipment grade, the overall effect is more obvious for our company’s product...
inquiry
detail
Factory Outlets Single Circuit Breaker - C45 1P Miniature Circuit Breaker – DaDa
Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1P...
inquiry
detail
Factory Cheap Hot mccb - DAM3-1000 MCCB Molded Case Circuit Breaker – DaDa
Overview The rated current of DAM3-1000 molded case circuit breaker can up to 690A, it’s generally used in the power distribution circuit to distribute power and protect circuit and power equipment from overloaded, short circuit, under voltage failure damage, in which alternating current 50-60Hz, rated direct-current 1000A. Compared to the DAM1 series, the DAM3 series are designed for smaller volume, higher breaking capacity, offering better energy savings. Electrical Parameters of DAM3...
inquiry
detail
Fast delivery Marine Circuit Breaker - C45 1P Miniature Circuit Breaker – DaDa
Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1P...
inquiry
detail
China wholesale Electronic Rcbo - DAB7LN-40 series DPN Residual Current Operation Circuit Breaker(RCBO) – DaDa
Installation method: Using 35mm guide rail according to IEC standard Terminal type: Dual-purpose terminal can be connected to the bus bar and conductor. Terminal connection ability: conductor 1-25mm2, bus bar thickness 0.8-2mm Guide rail: DIN35guide rail Functions of DAB7LN-40 residual current circuit breaker Short circuit protection, overload protection and isolation. Electrical Parameters of DAB7LN-40 Residual Current Circuit Breaker Number of poles 1P+N(18mm) Rated frequency 50-60H...
inquiry
detail
Manufacturer for 10a Mccb - DAM1 Series Thermal Overload Operation Moulded Case Circuit Breaker(Fixed type) – DaDa
Thermal-Magnetic Circuit Breakers Thermal protection function:(For protection under over load conditions) Bimetal, which provides thermal protection, consists of combination of two metals with different extension coefficients under heat. When bimetal is heated, it bends towards the metal with less extension. In this way, a notch that assists opening of the breaker mechanism is released to disable the breaker. Bending speed of bimetal is in direct proportion with size of the current passing t...
inquiry
detail
Good Wholesale Vendors Automotive Circuit Breaker - C45 3P Miniature Circuit Breaker – DaDa
Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1P...
inquiry
detail
<<
< Previous
184
185
186
187
188
189
190
Next >
>>
Page 187 / 463
Hit enter to search or ESC to close