    Installation and Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. 2. The...
  • Trending Products Air Break Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa

    Trending Products Air Break Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa

    Technical parameter of DAB7-100 8kA miniature circuit breaker Standard of conformity: IEC60898, GB10963 Rated voltage: 230/400V, 50HZ Rated breaking capacity: 10KA (6-63A), 8KA (80-100A) Protection grade: IP20 Flame retardant grade: grade2 Endurance (power-driven): no less than 8,000 times of opening Endurance (manual operation): no less than 20,000times of opening Mechanical parameters of DAB7-100 8kA miniature circuit breaker Electric wire: 1~35mm2 Connection mode: There are two kinds of co...
  • 2018 Good Quality Rcbo Electrical - RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection – DaDa

    2018 Good Quality Rcbo Electrical - RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection – DaDa

    Introduction Residual current operated circuit breakers with overcurrent protection ABDT-63 are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection.  They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting.
  • China wholesale Motor Circuit Protector - GV-M Motor Protection Circuit Breaker – DaDa

    China wholesale Motor Circuit Protector - GV-M Motor Protection Circuit Breaker – DaDa

    Application GV series motor protection circuit breaker are mainly used fo the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A) ...
  • 2018 High quality Electromagnetic Rccb - DAL7-63 Residual Current Circuit Breaker(RCCB) – DaDa

    2018 High quality Electromagnetic Rccb - DAL7-63 Residual Current Circuit Breaker(RCCB) – DaDa

    Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)...
  • Renewable Design for Time Delay Circuit Breaker - C65 MCB – DaDa

    Renewable Design for Time Delay Circuit Breaker - C65 MCB – DaDa

    ■ Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A ■ Rated working voltage: 110V, 230V ~ (1P, 1P + N), 400V ~ (2 ~ 4P, 3P + N) ■ Isolation □ Mechanical contact indication window, realistic cut-off instructions □ The window is green and the contact is in the open state. The window is red and the contact is in the closed state ■ Impulse withstand voltage: 4kV ■ Max withstand current: 6kA Circuit Breaker ■ Mechanical life: 20,000 times ■ Electrical life: 10000 times ■ Am...
  • Professional China Distribution Box Plastic - Modular Plastic Empty Enclosure For MCB IP40 (TXM series) Plastic base – DaDa

    Professional China Distribution Box Plastic - Modular Plastic Empty Enclosure For MCB IP40 (TXM series) Plastic base – DaDa

    Model Description TXM: series of distribution box Numbers of circuit:4,6,8,12,15,18,24,36 M:means Open mounted R:means Concealed mounted A:the cover is transparent P: plastic base Parameters ▪ Rated current: 63 [A] ▪ Short-circuit making current: 10 (KA) ▪ Shell protection grade: IP40; ▪ Shell material: ABS polymeric carbon ▪ Color: White ▪ Face covering: Transparent Outline Dimension    Surface    Flush   TXM distribution box(plastic)      Carton L*W*H(cm)   (PCS/CTN) G.W....
  • Newly Arrival Residual Circuit Breaker - DAB6-100 Miniature Circuit Breaker – DaDa

    Newly Arrival Residual Circuit Breaker - DAB6-100 Miniature Circuit Breaker – DaDa

    Application DAB6-100 is such features as delicate appearance, light weight, excellent and reliableperformance, high breaking capacity, rapid tripping and mounted by rail. Its enclosure and com-ponents adopts high fire-retarding and shock-resistance plastic of long durability. It mainly servesfor protecting the circuits of AC 50Hz, 230V of single pole, 400V of two poles or three or fourpoles from overload or short-circuit, and also for unfrequent making and breaking electricalapparatus and lig...
  • 2018 High quality 4 Pole Earth Leakage Circuit Breaker – DAM1L Series Earth Leakage protection Circuit Breaker (ELCB) – DaDa

    2018 High quality 4 Pole Earth Leakage Circuit Breaker – DAM1L Series Earth Leakage protection Circuit Breaker (ELCB) – DaDa

    Under normal conditions,It can also be used for infrequent switching of lines. This circuit breaker also has the following protection: • It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection. • Provide protection against the danger of increasing ground voltage due to insulation damage; • Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection. • Circuit breaker...
  • Professional China Abb Contactor - Contactor – DaDa

    Professional China Abb Contactor - Contactor – DaDa

    Introduction The structure of DA Type’s contactor is compact ;its volume is small;long perfomance life;Working stability and reliability ;installation is easy maintenance .Accessories of auxiliary contacts are plentiful it meet the various different market needs. It is mainly applied to control in motors ,electric line ,code wire ,bypass and lighting etc. of civilian and Industry. The main technical data: Main Circuit Rating Current: 9一370 A Motor power: 4一200KW (400V,AC-3)
  • China Factory for Home Circuit Breaker - C45 2P Miniature Circuit Breaker – DaDa

    China Factory for Home Circuit Breaker - C45 2P Miniature Circuit Breaker – DaDa

    Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1P 2P...
  • Factory Cheap Hot Rcbo 2p - RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection – DaDa

    Factory Cheap Hot Rcbo 2p - RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection – DaDa

    Introduction Residual current operated circuit breakers with overcurrent protection ABDT-63 are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection.  They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting.