product

  • Newly Arrival Residual Circuit Breaker - DAB7 L7 Mini circuit breaker – DaDa

    Newly Arrival Residual Circuit Breaker - DAB7 L7 Mini circuit breaker – DaDa

      Product Model Pole Trip type Rated current DAB7-63 1P C 63 1P 2P 3P 4P B:Type B C:Type C D:Type D 1:1A 10:10A 32:32A 2:2A 16:16A 40:40A 3:3A 20:20A 50:50A 4:4A 25:25A 63:63A 6:6A   Normal operating conditions and installation conditions   ■ Ambient air temperature of L7 6/10KA Miniature Circuit Breaker: -5℃~40℃, and average temperature in 24h below +35℃. ■ Altitude of the installation site should not exceed 2000m. ■ Atmospheric relative humidity at ...
  • Factory Cheap Hot mccb - DAM10 Molded Case Circuit Breaker NSX250 – DaDa

    Factory Cheap Hot mccb - DAM10 Molded Case Circuit Breaker NSX250 – DaDa

    DAM10 Schneider MCCB Circuit Breaker Technical Data Type Rated current(A) Poles Rated insulating voltage(V) Rated operating voltage(V) Arcing over distance(mm) Icu (kA) Ics (kA) Operating performance(time) DAM10-100D 12.5,16,20,25,32,40 50,63,80,100 3,4 750 690 0 18 18 1500 8500 DAM10-100N 25 25 DAM10-100H 70 70 DAM10-100L 150 150 DAM10-160D 100,125,160 25 25 1500 7000 DAM10-160N 36 36 DAM10-160H 70 70...
  • Renewable Design for Time Delay Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa

    Renewable Design for Time Delay Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa

    Technical parameter of DAB7-100 8kA miniature circuit breaker Standard of conformity: IEC60898, GB10963 Rated voltage: 230/400V, 50HZ Rated breaking capacity: 10KA (6-63A), 8KA (80-100A) Protection grade: IP20 Flame retardant grade: grade2 Endurance (power-driven): no less than 8,000 times of opening Endurance (manual operation): no less than 20,000times of opening Mechanical parameters of DAB7-100 8kA miniature circuit breaker Electric wire: 1~35mm2 Connection mode: There are two kinds of co...
  • Manufacturer for 45a Rcbo - DABL-63 RCBO 6KA Residual Current Operated Circuit Breaker – DaDa

    Manufacturer for 45a Rcbo - DABL-63 RCBO 6KA Residual Current Operated Circuit Breaker – DaDa

     Advantages • Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series. • The most subtle electric shock hazard protection in case of direct contact with conducting parts. • Independent contact position indicator. • Wide range of operating temperatures from –25 to +40° С. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. • “TEST”button for checking the ...
  • Professional China Motor Start Circuit Breaker - GV-M Motor Protection Circuit Breaker – DaDa

    Professional China Motor Start Circuit Breaker - GV-M Motor Protection Circuit Breaker – DaDa

    Application GV series motor protection circuit breaker are mainly used fo the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A) ...
  • Best quality Adjustable Circuit Breaker - DAB5 series Miniature Circuit breaker(MCB) – DaDa

    Best quality Adjustable Circuit Breaker - DAB5 series Miniature Circuit breaker(MCB) – DaDa

    >> Introduction DAB5-63  are intended for protecting distribution and group systems having different loads: - electric appliances, lighting – V characteristic switches; - drives with moderate starting currents (compressor, fan group) – C characteristic switches; - drives with high starting currents (hoisting mechanisms, pumps) – D characteristic switches; Miniature circuit breaker DAB5-63 are recommended for use in electrical distribution panels of residential and public bui...
  • Professional China molded case circuit breaker - DAM1-250 MCCB Moulded Case Circuit Breaker – DaDa

    Professional China molded case circuit breaker - DAM1-250 MCCB Moulded Case Circuit Breaker – DaDa

    Thermal-Magnetic Circuit Breakers Thermal protection function:(For protection under over load conditions) Bimetal,  which provides thermal protection, consists of combination of two metals with different extension coefficients under heat. When bimetal is heated, it bends towards the metal with less extension. In this way, a notch that assists opening of the breaker mechanism is released to disable the breaker. Bending speed of bimetal is in direct proportion with size of the current passing t...
  • Good Quality Residual Current Circuit Breaker - DAL6-63 Residual Current Circuit Breaker(RCCB) – DaDa

    Good Quality Residual Current Circuit Breaker - DAL6-63 Residual Current Circuit Breaker(RCCB) – DaDa

    Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)...
  • New Arrival China Industrial circuit breaker – Thermal Adjustable Type MCCB – DaDa

    New Arrival China Industrial circuit breaker – Thermal Adjustable Type MCCB – DaDa

    DAM1 series adjustable range of Moulded Case Circuit Breakers are designed and manufactured to world-class standards.Provide overload and short-circuit protection for all applications.The thermal elements, adjustable over a wide band,make these MCCBs ideal for any distribution application. Advantages •  16A to 1600A in 6 frame sizes in three pole and four pole with switched execution. •  Compact dimensions •  Adjustable thermal setting(70-100%)In. •  Push to trip button provision. •  Separate...
  • High Quality for 1 Pole Circuit Breaker - HVS  MCB  circuit breaker – DaDa

    High Quality for 1 Pole Circuit Breaker - HVS MCB circuit breaker – DaDa

    Safety Terminals To avoid improper cable termination, the safety terminals guide the cable towards the cage terminal for systematic termination Bi Stable Clip Every device is provided with a dual position DIN rail clip, so it becomes much easier to change a device from a device bank connected to a bus-bar, without disturbing the existing wiring Large Cable Terminals Suitable for copper and aluminum cables, these terminals are compatible with cables upto 35 mm 2 cross section area ...
  • China wholesale Mccb With Earth Leakage Protection - DAM1L-630 CBR ELCB Earth Leakage Protection Circuit Breaker – DaDa

    China wholesale Mccb With Earth Leakage Protection - DAM1L-630 CBR ELCB Earth Leakage Protection Circuit Breaker – DaDa

    Introduction DAM1L series residual current (leakage) circuit breaker (hereinafter referred to as circuit breaker) is a new series of residual current (leakage) successfully developed by using international standard design and advanced manufacturing technology. Protected moulded case type circuit breaker. The rated insulation voltage of circuit breakers of this series is 400V (Inm is less than 160A) and 690V (Inm is more than 250A), which is mainly used for ac 50Hz and rated In a power distrib...
  • 2018 High quality Small circuit breaker - DAB6  MCB – DaDa

    2018 High quality Small circuit breaker - DAB6 MCB – DaDa

    Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa...