  • Excellent quality 200 Amp Circuit Breaker - DAB6  MCB – DaDa

    Excellent quality 200 Amp Circuit Breaker - DAB6 MCB – DaDa

    Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa...
  • Top Suppliers 4 Pole Circuit Breaker - MCB Auxiliary Alarm Contact – DaDa

    Top Suppliers 4 Pole Circuit Breaker - MCB Auxiliary Alarm Contact – DaDa

    Use classes Ue(V) Ie(A) Number of contacts AC-12 230 2 2 groups of transfer contacts AC-15 230 1 DC-12 110 0.5 Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt t...
  • New Fashion Design for Air circuit breaker - MCB Auxiliary Alarm Contact – DaDa

    New Fashion Design for Air circuit breaker - MCB Auxiliary Alarm Contact – DaDa

    Use classes Ue(V) Ie(A) Number of contacts AC-12 230 2 2 groups of transfer contacts AC-15 230 1 DC-12 110 0.5 Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt t...
  • Well-designed Circuit Breaker Protection - DAB6-63 with transparent cover series miniature circuit breaker – DaDa
  • 8 Year Exporter 20 Amp Circuit Breaker - MCB Shunt Release – DaDa

    8 Year Exporter 20 Amp Circuit Breaker - MCB Shunt Release – DaDa

    Installation and Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. 2. The...
  • Best-Selling 16a Circuit Breaker - C65 MCB – DaDa

    Best-Selling 16a Circuit Breaker - C65 MCB – DaDa

    ■ Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A ■ Rated working voltage: 110V, 230V ~ (1P, 1P + N), 400V ~ (2 ~ 4P, 3P + N) ■ Isolation □ Mechanical contact indication window, realistic cut-off instructions □ The window is green and the contact is in the open state. The window is red and the contact is in the closed state ■ Impulse withstand voltage: 4kV ■ Max withstand current: 6kA Circuit Breaker ■ Mechanical life: 20,000 times ■ Electrical life: 10000 times ■ Am...
  • 100% Original Single Pole Circuit Breaker - DAB7 Series Miniature Circuit Breaker(MCB) – DaDa

    100% Original Single Pole Circuit Breaker - DAB7 Series Miniature Circuit Breaker(MCB) – DaDa

     Advantages • Two types of overcurrent protection – thermal and electromagnetic. • High Breaker capacity 10KA • Independent contact position indicator. • DIN rail latch with a double fixed position. • Wide range of operating temperatures from –40 to +50° С. • Wide engagement lever with improved contact area. • Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection. Technical Features MCB DAB7-63 For protection of general power distribution (IEC/E...
  • Factory source House Circuit Breaker - DAB6  MCB – DaDa

    Factory source House Circuit Breaker - DAB6 MCB – DaDa

    Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa...
  • Manufacturer for 45a Rcbo - DAB7LN-40 series DPN Residual Current Operation Circuit Breaker(RCBO) – DaDa

    Manufacturer for 45a Rcbo - DAB7LN-40 series DPN Residual Current Operation Circuit Breaker(RCBO) – DaDa

    Installation method: Using 35mm guide rail according to IEC standard Terminal type: Dual-purpose terminal can be connected to the bus bar and conductor. Terminal connection ability: conductor 1-25mm2, bus bar thickness 0.8-2mm Guide rail: DIN35guide rail Functions of DAB7LN-40 residual current circuit breaker Short circuit protection, overload protection and isolation. Electrical Parameters of DAB7LN-40 Residual Current Circuit Breaker Number of poles 1P+N(18mm) Rated frequency 50-60H...
  • Good Quality Shunt Release - Plug-In And Draw-Out Device – DaDa

    Good Quality Shunt Release - Plug-In And Draw-Out Device – DaDa

     CM 1 Plug-in Version Accessory Type Scope of application Specification and quantities Contact pin Arc-isolation plate and quantities Plug-in version install using hexagonal screw and quantities Circuit breaker install using screw and quantities Contact pin fixed screw and quantities User bind the board install using screw and quantities 63 Type plug-in version CM1-63,NM1-63,CDM1-63,TM30-63 1 6 4 4-M6X23 4-M3X18 6-M5copper nut 6-M5X10 100 Type plug-...
  • Cheap PriceList for 50 Amp Circuit Breaker - DAB5 MCB – DaDa

    Cheap PriceList for 50 Amp Circuit Breaker - DAB5 MCB – DaDa

    Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa...
  • Manufacturing Companies for 15 Amp Circuit Breaker - C45 2P Miniature Circuit Breaker – DaDa

    Manufacturing Companies for 15 Amp Circuit Breaker - C45 2P Miniature Circuit Breaker – DaDa

    Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1P 2P...