China wholesale Distribution Box Iron Base - MCB Enclosure (HAG series) – DaDa
Technique parameter Distribution box rated current: 1 way to 4 way:50A 6 way to 18 way:63A Material Insutation: Fire-proof type refractory material Color: Whitie color standard: accord with IEC X40439-3 Protective Degree IEC60529: IP30 Fire-resistant andanomaly heat abiliy IEC60529-1 standard,650C/30sec Compositian,structure. Removable matte blocks to increase the poles. The removable various size holes are available on the box of up and down,bott... -
2018 wholesale price Rccb - DAL3-63 Residual Current Circuit Breaker(RCCB) – DaDa
Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)... -
Factory Cheap Hot mccb - DAM1 1600 electronic type Moulded case circuit breaker(MCCB) – DaDa
Advantages • Wide range:100A to 1600A(AC) • Compact dimensions • Adjustable thermal setting(40-100%)In. • Adjustable magnetic setting(1.5-12times)In. • Push to trip button provision. • Separate main and arcing contacts • Wide range of accessories. Electronic Release Characteristic Curve Electronic Release(Electronic Trip Unit) Physical Parameters Of Dam1 Mccb Molded Case Circuit Breaker Category (EN 60947-2/IEC 60947-2) Endurance Model Pole Dielectric Pro... -
Chinese wholesale Rcbo Protection - DABL-63 RCBO 6KA Residual Current Operated Circuit Breaker – DaDa
Advantages • Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series. • The most subtle electric shock hazard protection in case of direct contact with conducting parts. • Independent contact position indicator. • Wide range of operating temperatures from –25 to +40° С. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. • “TEST”button for checking the ... -
Trending Products Air Break Circuit Breaker - BA47-29 series Miniature Circuit breaker(MCB) – DaDa
>> Introduction BA47-29 are intended for protecting distribution and group systems having different loads: - electric appliances, lighting – V characteristic switches; - drives with moderate starting currents (compressor, fan group) – C characteristic switches; - drives with high starting currents (hoisting mechanisms, pumps) – D characteristic switches; Miniature circuit breaker BA47-29 are recommended for use in electrical distribution panels of residential and public bui... -
High Quality Mpcb Circuit Breaker - GV-M Motor Protection Circuit Breaker – DaDa
Application GV series motor protection circuit breaker are mainly used fo the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A) ... -
China wholesale Mccb With Earth Leakage Protection - DAM1 -160L ELCB Earth Leakage protection circuit breaker1 – DaDa
This circuit breaker also has the following protection: • It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection. • Provide protection against the danger of increasing ground voltage due to insulation damage; • Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection. • Circuit breakers with rated current of 500A and below can also be used for infrequent start, br... -
Good quality 300 Amp Circuit Breaker - HVS MCB with window – DaDa
Safety Terminals To avoid improper cable termination, the safety terminals guide the cable towards the cage terminal for systematic termination Bi Stable Clip Every device is provided with a dual position DIN rail clip, so it becomes much easier to change a device from a device bank connected to a bus-bar, without disturbing the existing wiring Large Cable Terminals Suitable for copper and aluminum cables, these terminals are compatible with cables upto 35 mm 2 cross section area ... -
2018 wholesale price Under Voltage Release - Alarm Contacts – DaDa
Alarm Contacts Application The alarm contacts is used for alarm open action of current ,and under voltage of circuit and equipment. Alarm contacts size: 1N/O and 1N/C Wiring Diagram Of Auxiliary Contacts: State of MCCB State of alarm contacts diagram of wiring Close position Open position DAM1-125/160BC DAM1(ABB)-125,160A DAM1-250/400BCDAM1(ABB)-250A,400A DZ20-100BCDZ20-100A DZ20-225BC DZ20-225A ... -
High Quality micro circuit breaker - DAB5 MCB – DaDa
Normal operating conditions and installation conditions Ambient air temperature: -5℃~40℃, and average temperature in 24h below +35℃. Altitude of the installation site should not exceed 2000m. Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. For example, in +20℃ , the relative humidity can reach 90%. It should be noted that, due to temperature changes, for appropriate condensation produced occa... -
High Quality Waterproof Distribution Box - Plastic Empty Enclosure For MCB IP65 (HT Series) Water Proof Distribution Box – DaDa
Features Panel is the ABS material far the engineering, high strength, never change color, the transparent material is PC. Cover push-type opening and Closing Face covering of the distribution box adopts the push一type opening and closing mode, the face mask can be opened by pressing lightly, the self-locking positioning hinge structure is provided when opening Wiring design of the power distribution box The guide rail support plate can be lifted to the highest movable point, it is no longer ... -
2018 Good Quality Rccb Protection - DAL5-63 Residual Current Circuit Breaker(RCCB) – DaDa
Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)...