OEM Manufacturer Outdoor Circuit Breaker - DAB7-125 Series Miniature Circuit Breaker(MCB) – DaDa
Advantages • Trip Free mechanism • High Breaker capacity 15KA • Positive contact indication • Thermal and magnetic trip function • Current limiting design for short circuit fault protection • CE marking,Semko product • Specification:IEC 60947-2 Design Features Large Cable Terminals Suitable for copper and aluminum cables, these terminals are compatible with cables upto 35mm2 cross section area. Technical Features MCB DAB7-125 For protection of general power distribution (IEC/EN 60947-2) ... -
Low price for 40 Amp Circuit Breaker - C65 MCB – DaDa
■ Rated current: 1A, 2A, 3A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A ■ Rated working voltage: 110V, 230V ~ (1P, 1P + N), 400V ~ (2 ~ 4P, 3P + N) ■ Isolation □ Mechanical contact indication window, realistic cut-off instructions □ The window is green and the contact is in the open state. The window is red and the contact is in the closed state ■ Impulse withstand voltage: 4kV ■ Max withstand current: 6kA Circuit Breaker ■ Mechanical life: 20,000 times ■ Electrical life: 10000 times ■ Am... -
OEM/ODM China Mccb 300 A - DAM4 Series Moulded Case Circuit Breaker(MCCB) – DaDa
Application DAM4 series MCCB is applicable circuit of AC 50/60Hz, rated current up to 400A, for distribute energy of electricity & infrequent making & breaking circuit in normal conditions. The products conforms to IEC60947-2. Specification Type DAM4-125 DAM4-160 DAM4-250 DAM4-400 Poles number 3 3 3 3 Rated current In(A) 25~125 25~160 125~250 125~400 Rated working voltage Ue(V) (50/60Hz) 500 500 600 600 Rated working voltage Ue (V) ... -
High Quality Rcbo Circuit Breaker - DABL-63 RCBO 6KA Residual Current Operated Circuit Breaker – DaDa
Advantages • Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series. • The most subtle electric shock hazard protection in case of direct contact with conducting parts. • Independent contact position indicator. • Wide range of operating temperatures from –25 to +40° С. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. • “TEST”button for checking the ... -
Professional China Id Rccb - DAL7-63 Residual Current Circuit Breaker(RCCB) – DaDa
Main Parameters Technical parameter parameter value Rated voltage :Un (V) 240V ~ 1P+N,415 V ~ 3P+N Rated current (A) In: 16 A, 20 A, 25 A, 32 A, A, 40 to 50 A, 63 A Rated residual operating current I (A): 0.03,0.1,0.3 The number of 1 p + N, 3 p + N AC type, A type according to the working condition with dc shunt Delay type S type Rated limiting short circuit current Inc(A) :6000 Rated limiting residual short circuit current I c(A) :6000 Rated switching and breaking capacity Im(A): 500(In 50A)... -
Hot New Products 30 Amp Mini Circuit Breaker - MCB Auxiliary Alarm Contact – DaDa
Use classes Ue(V) Ie(A) Number of contacts AC-12 230 2 2 groups of transfer contacts AC-15 230 1 DC-12 110 0.5 Installation And Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt t... -
China wholesale thermal overload circuit breaker - DAM1 400 MCCB ABB ISOMAX – DaDa
Advantages •Easy independent installation of auxiliary devices: •Alarm contact; •Auxiliary contact; •Under voltage release; •Shunt release; •Handle operating mechanism; •Electrical operating mechanism; •Plug-in device; •Draw-out device;. •Standard set of each circuit breaker consists of connecting busbars or cable lugs, phase separators, a set of screws and nuts for its mounting ont•an installation panel. •With the help of special clamp 125 and 160 units can be installed ont•a DIN-rail. •Weig... -
Good Quality Residual Current Circuit Breaker With Overcurrent Protection - RCBO 4.5KA Residual Current Circuit Breaker With Overcurrent Protection – DaDa
Introduction Residual current operated circuit breakers with overcurrent protection ABDT-63 are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection. They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting. -
2018 High quality 25 Amp Rcbo - DAB7LN-40 series DPN Residual Current Operation Circuit Breaker(RCBO) – DaDa
Installation method: Using 35mm guide rail according to IEC standard Terminal type: Dual-purpose terminal can be connected to the bus bar and conductor. Terminal connection ability: conductor 1-25mm2, bus bar thickness 0.8-2mm Guide rail: DIN35guide rail Functions of DAB7LN-40 residual current circuit breaker Short circuit protection, overload protection and isolation. Electrical Parameters of DAB7LN-40 Residual Current Circuit Breaker Number of poles 1P+N(18mm) Rated frequency 50-60H... -
High Quality Rccb Circuit Breaker - RTF1L-63 Residual Current Circuit Breaker(RCCB) – DaDa
Advantage Specification Frame class 63A Rated working voltage 240/415V Rated frequency 50/60Hz Rated working current 16, 20, 25, 32, 40, 50, 63A Rated residual operating current 0.03, 0.1, 0.3A Rated residual un-operating current 0.015, 0.05, 0.15A Sensibility AC Type, A Type, B Type Maximum operating time IΔn t≤0.1s, 5IΔn t≤0.04 Rated making and breaking capacity In≤50A 500A, In=63A 630A Limiting value of un-operating current 6In Rated limiting short-circuit curre... -
Professional China Motor Start Circuit Breaker - GV-M Motor Protection Circuit Breaker – DaDa
Application GV series motor protection circuit breaker are mainly used fo the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A) ... -
Good Quality Earth Leakage Circuit Breaker - DAM1L Series Earth Leakage protection Circuit Breaker (ELCB) – DaDa
Under normal conditions,It can also be used for infrequent switching of lines. This circuit breaker also has the following protection: • It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection. • Provide protection against the danger of increasing ground voltage due to insulation damage; • Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection. • Circuit breaker...