product

  • High reputation 250 Amp Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa

    High reputation 250 Amp Circuit Breaker - DAB7-100 8kA MCB Switch Miniature Circuit Breaker – DaDa

    Technical parameter of DAB7-100 8kA miniature circuit breaker Standard of conformity: IEC60898, GB10963 Rated voltage: 230/400V, 50HZ Rated breaking capacity: 10KA (6-63A), 8KA (80-100A) Protection grade: IP20 Flame retardant grade: grade2 Endurance (power-driven): no less than 8,000 times of opening Endurance (manual operation): no less than 20,000times of opening Mechanical parameters of DAB7-100 8kA miniature circuit breaker Electric wire: 1~35mm2 Connection mode: There are two kinds of co...
  • High Quality Heat Shrink Junction Box - MPH Series Busbar Conjunction Box (Heat Shrink Junction Box) 1kv10kv35kv – DaDa

    High Quality Heat Shrink Junction Box - MPH Series Busbar Conjunction Box (Heat Shrink Junction Box) 1kv10kv35kv – DaDa

    Application Main busbar connector box in the electrical equipment at the electrical connection of the insulation protection, and high and low voltage switchgear circuit breakers are not deformed, heat is not deformed, heat does not shrink, the appearance of the corners, wall thickness Uniform, accurate size, stable performance, smooth and meticulous appearance, long service life, etc., can better highlight the equipment grade, the overall effect is more obvious for our company’s product...
  • Good Quality Motor Protection Circuit Breaker - GV-M Motor Protection Circuit Breaker – DaDa

    Good Quality Motor Protection Circuit Breaker - GV-M Motor Protection Circuit Breaker – DaDa

    Application GV series motor protection circuit breaker are mainly used fo the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A) ...
  • Wholesale Micro Circuit Breaker - C45 2P Miniature Circuit Breaker – DaDa

    Wholesale Micro Circuit Breaker - C45 2P Miniature Circuit Breaker – DaDa

    Application C45 is applicable to a line of AC 50Hz/60Hz, 230V in single pole, 400V in double, three,four poles for protecting overload and short circuit, and rated current up to 63A. It can also beused for infrequent line conversion under the normal condition.The breaker is applicable tolighting distribution system in industrial enterprise, commercially district, high-rise building anddwelling house. It conforms with the standards of IEC60898. Main Technical Parameter Type C45 Pole 1P 2P...
  • China Cheap price Mccb With Elcb - DAM1L Series Earth Leakage protection Circuit Breaker (ELCB) – DaDa

    China Cheap price Mccb With Elcb - DAM1L Series Earth Leakage protection Circuit Breaker (ELCB) – DaDa

    Under normal conditions,It can also be used for infrequent switching of lines. This circuit breaker also has the following protection: • It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection. • Provide protection against the danger of increasing ground voltage due to insulation damage; • Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection. • Circuit breaker...
  • Professional China molded case circuit breaker - DAM1 630 Series MCCB ABB ISOMAX – DaDa

    Professional China molded case circuit breaker - DAM1 630 Series MCCB ABB ISOMAX – DaDa

    Advantages •Easy independent installation of auxiliary devices: Alarm contact; Auxiliary contact; Under voltage release; Shunt release; Handle operating mechanism; Electrical operating mechanism; Plug-in device; Draw-out device;. •Standard set of each circuit breaker consists of connecting busbars or cable lugs, phase separators, a set of screws and nuts for its mounting ontan installation panel. •With the help of special clamp 125 and 160 units can be installed onta DIN-rail. •Weight and dim...
  • China OEM Three Phase Circuit Breaker - MCB Shunt Release – DaDa

    China OEM Three Phase Circuit Breaker - MCB Shunt Release – DaDa

    Installation and Use 1. This series of circuit breaker accessories are specially designed for use in conjnction with DAB7 (63 frame) circuit breakers and are not intended to be used alone. The circuit breaker has the following accessories Circuit breaker + auxiliary contact; circuit breaker + auxiliary alarm contact; circuit breaker +shunt trip; circuit breaker + shunt trip + auxiliary contact; circuit breaker + shunt trip + auxiliary alarm contact; circuit breaker + undervoltage trip. 2. The...
  • China Cheap price Electrical Operating Mechanism(Motor) - Auxiliary Contacts – DaDa

    China Cheap price Electrical Operating Mechanism(Motor) - Auxiliary Contacts – DaDa

    Application The auxiliary contacts is intended for automatical controlling of the auxiliary circuit of MCCB,such as indication of the open and close states of MCCB.  Auxiliary Contacts Size  1N/O and 1N/C  2N/O and2N/C  4N/O and 4N/C  Wiring Diagram Of Auxiliary Contacts State of MCCB State ofauxiliary contacts diagram of wiring Close position 1 set of auxiliary contacts,but2 sets of contacts to be supplied For Inm=63A-225A          2 set of auxiliary contacts,but4 sets...
  • Top Quality interruptor - DAB7 L7 Mini circuit breaker – DaDa

    Top Quality interruptor - DAB7 L7 Mini circuit breaker – DaDa

      Product Model Pole Trip type Rated current DAB7-63 1P C 63 1P 2P 3P 4P B:Type B C:Type C D:Type D 1:1A 10:10A 32:32A 2:2A 16:16A 40:40A 3:3A 20:20A 50:50A 4:4A 25:25A 63:63A 6:6A   Normal operating conditions and installation conditions   ■ Ambient air temperature of L7 6/10KA Miniature Circuit Breaker: -5℃~40℃, and average temperature in 24h below +35℃. ■ Altitude of the installation site should not exceed 2000m. ■ Atmospheric relative humidity at ...
  • Professional China A Type Ac Type Rcbo - DABL-63 Nova Series Residual Current Operated Circuit Breakers With Overcurrent Protection – DaDa

    Professional China A Type Ac Type Rcbo - DABL-63 Nova Series Residual Current Operated Circuit Breakers With Overcurrent Protection – DaDa

    Advantages • Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series. • The most subtle electric shock hazard protection in case of direct contact with conducting parts. • Independent contact position indicator. • Wide range of operating temperatures from –25 to +40° С. • Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection. • “TEST” button for checking the device’s ope...
  • 2018 wholesale price Motor Protection Circuit – GV2 Mpcb Motor Protection Circuit Breaker  – DaDa

    2018 wholesale price Motor Protection Circuit – GV2 Mpcb Motor Protection Circuit Breaker – DaDa

    Application GV-Me series motor protection circuit breaker are mainly used for the overload and short circuit protection of the motor in AC 50/60Hz, up to 660V, 0.1-80A power circuit, as a full-voltage starter to start and cut off the motor, under the AC3 load or for the overload and short circuit protection of the circuit and power equipment in the power distribution network. Specification Type Standard power ratings of 3-phase motors 50/60Hz in category AC-3 Current setting range (A)...
  • Hot New Products Tp Mccb - DAM1 Series Thermal Overload Operation Moulded Case Circuit Breaker(Fixed type) – DaDa

    Hot New Products Tp Mccb - DAM1 Series Thermal Overload Operation Moulded Case Circuit Breaker(Fixed type) – DaDa

    Thermal-Magnetic Circuit Breakers Thermal protection function:(For protection under over load conditions) Bimetal,  which provides thermal protection, consists of combination of two metals with different extension coefficients under heat. When bimetal is heated, it bends towards the metal with less extension. In this way, a notch that assists opening of the breaker mechanism is released to disable the breaker. Bending speed of bimetal is in direct proportion with size of the current passing t...
123456 Next > >> Page 1 / 469