China wholesale thermal overload circuit breaker - DAM3-250 MCCB Molded Case Circuit Breaker – DaDa Detail:
Overview
The rated current of the Dada DAM3-250 molded case circuit breaker can reach up to 250A. These electrical devices are suitable for power distribution circuits with an alternating current of 50-60Hz and a rated operating current to 1000A. They can also be used in electric motors for infrequent starting and overload protection as well as protection against short circuiting and undervoltage conditions.
Compared to the DAM1 series, the DAM3 series are designed for smaller volume, higher breaking capacity, offering better energy savings.
Electrical Parameters of DAM3-250 Molded Case Circuit Breaker
Rated current of frame size Inm [A] |
250 |
||||
Rated current [A] |
100-250 |
100-225 |
|||
Number of poles |
2 / 3 / 4 |
||||
Rated operating voltage |
(AC)50-60HZ [V] |
400/690 |
|||
DC [V] |
250/1000 |
||||
Rated impulse withstand voltage Uimp [KV] |
8 |
||||
Rated insulation voltage Ui [V] |
750 |
||||
Test voltage at industrial frequency for 1 min [V] |
3000 |
||||
Rated ultimate short-circuit breaking capacity Icu [KA] |
B |
C |
N |
S |
|
(AC)50-60HZ 220/230V [KA] |
30 |
36 |
50 |
75 |
|
(AC)50-60HZ 400/415V [KA] |
18 |
25 |
36 |
50 |
|
(AC)50-60HZ 690V [KA] |
6 |
8 |
12 |
15 |
|
(DC)250V-2 Poles in series |
18 |
22 |
30 |
40 |
|
(DC)500V-2 Poles in series |
9 |
12 |
15 |
20 |
|
(DC)750V-4 Poles in series |
16 |
18 |
22 |
30 |
|
(DC)1000V-4 Poles in series |
13 |
15 |
18 |
25 |
|
Rated service short-circuit breaking capacity, Ics [KA] | |||||
(AC)50-60HZ 220/230V [%Icu] |
60% |
60% |
60% |
50% |
|
(AC)50-60HZ 400/415V [%Icu] |
60% |
60% |
60% |
50% |
|
(AC)50-60HZ 690V [%Icu] |
60% |
60% |
60% |
50% |
|
category of utilization (EN 60947-2) |
A |
||||
Isolation condition |
Bitmap |
||||
Reference standard |
IEC/EN 60947-2/GB 14048.2 |
||||
Interchangeability |
Bitmap |
||||
Versions | Fixed |
Bitmap |
|||
Plug-in |
Bitmap |
||||
Draw-out | - |
Physical Parameters DAM3-250 Molded Case Circuit Breaker
Endurance |
Total cycles |
10000 |
|
Electrical endurance |
1500 |
||
Mechanical endurance |
8500 |
||
Basic dimensions-fixed version
|
3/4 Poies W[mm] |
70(2P) /104 /139 |
|
3/4 Poies H[mm] |
59 |
62.5 |
|
H1[mm] |
78.5 |
82 |
|
3/4 Poies L[mm] |
139 |
Introduction
The DAM3-250 molded case circuit breaker automatically cuts off the current when the current exceeds the release setting. The molded case refers to the plastic insulator used as the frame of the device to insulate the conductor and the metal grounding component.
Note: Product details are attached.
Product detail pictures:
Related Product Guide:
As for aggressive rates, we believe that you will be searching far and wide for anything that can beat us. We can easily state with absolute certainty that for such good quality at such charges we are the lowest around for China wholesale thermal overload circuit breaker - DAM3-250 MCCB Molded Case Circuit Breaker – DaDa , The product will supply to all over the world, such as: Angola, kazan, Grenada, We set "be a creditable practitioner to achieve the continuous development and innovation" as our motto. We would like to share our experience with friends at home and abroad, as a way to create a bigger cake with our joint efforts. We have several experienced R & D persons and we welcome OEM orders.
By Sara from Iran - 2018.10.09 19:07
The company has rich resources, advanced machinery, experienced workers and excellent services, hope you keep improving and perfecting your products and service, wish you better!
By Ellen from Indonesia - 2018.02.21 12:14