Overview
The rated current of the Dada DAM3-250 molded case circuit breaker can reach up to 250A. These electrical devices are suitable for power distribution circuits with an alternating current of 50-60Hz and a rated operating current to 1000A. They can also be used in electric motors for infrequent starting and overload protection as well as protection against short circuiting and undervoltage conditions.
Compared to the DAM1 series, the DAM3 series are designed for smaller volume, higher breaking capacity, offering better energy savings.
Electrical Parameters of DAM3-250 Molded Case Circuit Breaker
Rated current of frame size Inm [A] |
250 |
||||
Rated current [A] |
100-250 |
100-225 |
|||
Number of poles |
2 / 3 / 4 |
||||
Rated operating voltage |
(AC)50-60HZ [V] |
400/690 |
|||
DC [V] |
250/1000 |
||||
Rated impulse withstand voltage Uimp [KV] |
8 |
||||
Rated insulation voltage Ui [V] |
750 |
||||
Test voltage at industrial frequency for 1 min [V] |
3000 |
||||
Rated ultimate short-circuit breaking capacity Icu [KA] |
B |
C |
N |
S |
|
(AC)50-60HZ 220/230V [KA] |
30 |
36 |
50 |
75 |
|
(AC)50-60HZ 400/415V [KA] |
18 |
25 |
36 |
50 |
|
(AC)50-60HZ 690V [KA] |
6 |
8 |
12 |
15 |
|
(DC)250V-2 Poles in series |
18 |
22 |
30 |
40 |
|
(DC)500V-2 Poles in series |
9 |
12 |
15 |
20 |
|
(DC)750V-4 Poles in series |
16 |
18 |
22 |
30 |
|
(DC)1000V-4 Poles in series |
13 |
15 |
18 |
25 |
|
Rated service short-circuit breaking capacity, Ics [KA] | |||||
(AC)50-60HZ 220/230V [%Icu] |
60% |
60% |
60% |
50% |
|
(AC)50-60HZ 400/415V [%Icu] |
60% |
60% |
60% |
50% |
|
(AC)50-60HZ 690V [%Icu] |
60% |
60% |
60% |
50% |
|
category of utilization (EN 60947-2) |
A |
||||
Isolation condition |
Bitmap |
||||
Reference standard |
IEC/EN 60947-2/GB 14048.2 |
||||
Interchangeability |
Bitmap |
||||
Versions | Fixed |
Bitmap |
|||
Plug-in |
Bitmap |
||||
Draw-out | - |
Physical Parameters DAM3-250 Molded Case Circuit Breaker
Endurance |
Total cycles |
10000 |
|
Electrical endurance |
1500 |
||
Mechanical endurance |
8500 |
||
Basic dimensions-fixed version
|
3/4 Poies W[mm] |
70(2P) /104 /139 |
|
3/4 Poies H[mm] |
59 |
62.5 |
|
H1[mm] |
78.5 |
82 |
|
3/4 Poies L[mm] |
139 |
Introduction
The DAM3-250 molded case circuit breaker automatically cuts off the current when the current exceeds the release setting. The molded case refers to the plastic insulator used as the frame of the device to insulate the conductor and the metal grounding component.
Note: Product details are attached.
Product detail pictures:
Related Product Guide:
Our firm has been concentrating on brand strategy. Customers' satisfaction is our best advertising. We also offer OEM provider for China wholesale thermal overload circuit breaker - DAM3-250 MCCB Molded Case Circuit Breaker – DaDa , The product will supply to all over the world, such as: Honduras, Pakistan, Salt Lake City, We believe that good business relationships will lead to mutual benefits and improvement for both parties. We have established long-term and successful cooperative relationships with many customers through their confidence in our customized services and integrity in doing business. We also enjoy a high reputation through our good performance. Better performance will be expected as our principle of integrity. Devotion and Steadiness will remain as ever.
By Linda from Houston - 2017.04.18 16:45
We are really happy to find such a manufacturer that ensuring product quality at the same time the price is very cheap.
By Grace from Hungary - 2017.12.09 14:01